2.5.5 Alarm settings
Arm / Disarm method
: arming and disarming can be performed with external unit
(access keypad, key switch, radio controller etc.), and through the phone. For
arming/disarming with external unit one (Z6) or two (Z5 and Z6) inputs can be used
depending on the available switching signal:
o
0 - Always Armed
: it is not necessary to arm/disarm the module when used as
transmitter device. In this case select this mode and this way all 6 inputs remain
available for signal reception and the module will be armed permanently.
o
1 - Using switch
: arming and disarming is performed with switch or relay
contact, where one of the states of the switch (or compliant relay) arms, the
other state disarms the module. Closed contact on input Z6 (to V-) arms,
opening this contact disarms the module. In this case input Z6 cannot be used
as zone input.
o
2 - Using switch
: this mode corresponds to the previous, one but operates the
system inversely (closed contact disarms, open contact arms the module).
o
3 - One kind of impulse
: arms the system with a closed contact impulse on
input Z6 (to V-) and performs disarm with the following closed contact impulse
on the same input.
o
4 - Two kinds of impulses
: select this mode when arming and disarming have
to be performed by closed contact impulses on two different inputs. Such is e.g.
an RC module receiver where one relay is activated for a short time when
pressing the arming button and a second relay is activated when pressing the
disarming button. Closed contact impulse applied on input Z5 (to V-) arms, also
closed contact impulse applied to input Z6 (to V-) disarms the system. In this
mode inputs Z5 and Z6 cannot be used for zone function according to the
meaning.
o
5 - Two kind of impulses
: corresponds to the previous mode, but arming and
disarming is performed by impulsive opening of the closed contacts on inputs Z5
and Z6 (to V-).
Attention! Arming and disarming through phone and through the programming