background image

 

10

2.5.4  Phone number settings 

 

1 - 4. Phone number

: 4 user telephone numbers can be entered where alarms will be 

reported through voice call and/or SMS message (according to event settings). 

 

Acknowledgement

: three confirmation modes can be selected: 

o

 

0 - no ack.

:

 

event confirmation is not necessary 

o

 

1 - * = ack.

: event must be confirmed by pressing * key on the phone 

o

 

2 - * = ack, # = stop

: event must be confirmed by pressing 

*

 key on the phone, 

or the reporting of the given event to further phone numbers can be cancelled by 
pressing 

#

 key on the phone. 

(Reporting of all pending events waiting to be reported can be canceled by 
entering *

module password

# on the phone e.g. *1111# for default passw.). 

 

 

Caller ID

: there are seven modes of caller identification for incoming calls: 

o

 

0 - none

: password is requested before accepting commands 

o

 

1 - no pwd req.

: commands are accepted without requesting the password 

o

 

2 - relay ON

: identifies the caller and activates the relay with free call 

o

 

3 - relay On + pick up

: identifies the caller, activates the relay, then picks up to 

allow further controls through the phone 

o

 

4 - Arm

: arming the module with free call (from version v3.10) 

o

 

5 - Disarm

: disarming the module with free call (from version v3.10) 

o

 

6 - Arm/Disarm

: first free call arms, next free call disarms the module 

(from version v3.10) 

Attention! Arming and disarming the module by phone calls is only possible if 
arming/disarming mode 3, 4 or 5 is set! 

 

SMS forwarding 1-2

: the module forwards the SMS messages received on its SIM 

card to the telephone numbers entered here. This is useful e.g. to forward the 
information received from the GSM provider about the balance of prepay type SIM 
cards. (If these fields are blank, the module ignores incoming SMS messages). 

Important! Never enter here the phone number of the SIM card placed into 
the module, because this would initiate an infinite loop of SMS sent to itself 
right after the first incoming SMS, causing significant expense!

 

 

1-2. Central Phone Nr.

: enter here the phone numbers of the monitoring station(s) 

 

User ID

: the four-digit (0..9,A,B,C,D,E,F characters) user identification number can be 

specified here, which is necessary for reporting to monitoring station. 

 

Monitoring station reporting mode

: report and respectively request confirmation 

to/from only one of the phone numbers of monitoring station, or both phone numbers. 

Содержание GSM Pager3 Z6

Страница 1: ...GSM Pager3 Z6 INSTALLATION AND USER MANUAL for module version v3 20 and up Document version 1 3 05 12 2013...

Страница 2: ...umber settings 10 2 5 4 1 Setting phone numbers through SMS 11 2 5 5 Alarm settings 12 2 6 Changing the module s password 13 2 7 Event log 14 2 8 Reading the module s version 15 2 9 Remote control and...

Страница 3: ...ion page The update procedure requires internet connection Here it can be also configured if the program should search for updates automatically upon each opening or this is performed manually by clic...

Страница 4: ...next to the USB icon in the upper right corner of the main window then the module version is displayed The program does not request the module password if the default password is set in the module 11...

Страница 5: ...the alarming time By keeping the mouse pointer above any cell of the table details of the specific event will be displayed If you wish to copy this content hold down CTRL button on keyboard and the de...

Страница 6: ...pens a window showing detailed information about the procedures running in the module only for troubleshooting Message flow can be started and stopped by pressing Start Stop button Messages can be sav...

Страница 7: ...active state of the zones can be set here Normally Open the input should be connected to V terminal to generate an event Normally Close the input should be connected by default to V terminal and then...

Страница 8: ...g 0 9 A B C D E F characters for reporting to monitoring station e g 130 alarm however this code is also used for restoration since the module will indicate automatically in the appropriate part of th...

Страница 9: ...means if it has been activated it will not deactivate itself can only be deactivated through phone call if enabled or will deactivate on disarm if Turn off Relay 1 on Disarm is set this function does...

Страница 10: ...e phone o 4 Arm arming the module with free call from version v3 10 o 5 Disarm disarming the module with free call from version v3 10 o 6 Arm Disarm first free call arms next free call disarms the mod...

Страница 11: ...are not configured in the module but in this case the module password is requested to be entered in the command after the parameters in the following way e g UX phone number PWD 1111 The procedure is...

Страница 12: ...ious one but operates the system inversely closed contact disarms open contact arms the module o 3 One kind of impulse arms the system with a closed contact impulse on input Z6 to V and performs disar...

Страница 13: ...n This limitation option is only available in Always armed mode Test report frequency the frequency of test report messages can be set in hours 0 255 This means the module will send test reports in th...

Страница 14: ...ks displayed in T1 T4 S1 S4 and C1 C2 columns o report processing in progress o reporting successful o R reporting already performed in other way therefore reporting is not needed o reporting failed o...

Страница 15: ...sword denied 4 low tone beeps 0 Disarm 3 beeps 1 Arm 6 beeps 2 Armed status query Disarmed 3 beeps Armed 6 beeps 4 GSM signal strength query Number of beeps according to the actual GSM signal strength...

Страница 16: ...ON PWD yyyy CRQ Activation of Relay1 bistable mode If needed substitute yyyy with the module password see specifications below R1 OFF PWD yyyy CRQ Deactivation of Relay1 If needed substitute yyyy with...

Страница 17: ...ed Permanent Relay1 activated permanently bistable mode Relay1 deactivated Relay1 deactivated Unauthorized User Wrong or missing password Module reset executed Module settings are restored to factory...

Страница 18: ...ulty Red blinks fast Green blinks slower Event transmission in progress Green blinks impulsely and slowly Red is not lit GSM network is available system is disarmed Green and red blink impulsely and a...

Страница 19: ...antenna or find a more suitable place for the module The antenna should be placed outside the box in case of installing the unit into a metal box where the measured GSM signal is the highest possible...

Страница 20: ...uency GSM 900 1800 MHz 850 1900 MHz Max relay output load 5A 24VAC DC GSM phone type Simcom SIM900 Dimensions 84 x 72 x 32mm Weight 200g packed 300g 5 2 Contents of the package GSM Pager3 Z6 terminal...

Отзывы:

Похожие инструкции для GSM Pager3 Z6