3.5  SIM card socket 

The SIM card socket can be accessed by removing the cover of the aperture found on the 
module enclosure. The cover can be removed by pressing it with your fingernail towards the 
LED  at  the  end  where  the  gap  is  and  then  pulling  it  outwards.  Insert  the  SIM  card  in  the 
socket.  The  services  to  be  activated  on  the  SIM  card  installed  into  the 

Gate  Control  Pro

 

device  should  be  chosen  according  to  which  services  of  the  device  you  wish  to  use.  For 
usage with the smartphone application and for the functions that use e-mail sending mobile 
internet  service  is  necessary.  The functions that  use  SMS  sending  need  SMS  service  and 
the ones that use calls require GSM voice call service. For accessing the Internet the SIM 
card should use a public APN. 

  Installing the SIM card:

 

 

 

1.

  pull  the  metal  security  lock  of  the  SIM  socket 

towards the LED until it clicks

 

 

2.

 reach under the metallic security lock with your 

fingernail and pull it outwards to open the socket

 

 

3.

 slide the SIM card into the opened part with the 

contacts facing down, as shown in the figure

 

  Close back the opened part together with the SIM 

card

 

  Press  down  carefully  the  metallic  security  lock 

and pull it towards the side of the enclosure until it 
clicks.

 

3.6  Connecting the antenna 

Connect the 

GSM antenna to the FME-M socket. The module comes with an antenna 

which provides good transmission under normal reception circumstances. In case of 
experiencing signal strength problems or/and wave interference (fading), use another 
(directed) type of antenna or find a more suitable mounting place for the antenna.

 

3.7  Installation 

Please check the environment before installing: 

 

Verify the GSM signal strength with your mobile phone. It may happen that the 
signal  strength  is  not  sufficient  in  the  desired  mounting  place.  In  this  case  the 
planned installation place can be changed before mounting the device

 

Do  not  mount  the  unit  in  places  where  it  could  be  affected  by  strong 
electromagnetic disturbances (e.g. in the vicinity of electric motors, high voltage, 
etc.)

 

Do not mount the unit in wet places or places with high degree of humidity

Содержание GSM Gate Control Pro 1000

Страница 1: ...caller identification 5 different control modes 4 NO NC inputs 2 NO relay outputs 50 configurable access templates Configurable holidays Automatic timed controls 20 and 1000 user variant Reports the s...

Страница 2: ...nfiguring by computer via USB 11 4 3 Configuring by computer over the Internet 11 4 3 1 Adding a client identifier for the programming software 12 4 3 2 Managing SIM identifiers 13 4 3 3 Steps of remo...

Страница 3: ...ent permissions and access periods as well as custom access rules can be assigned The access periods can be configured by access templates which can be assigned to users The system will accept control...

Страница 4: ...while the position limit switch of gate B should be connected to input IN4 In case of control modes 3 4 and 5 the gate s position limit switch should be connected to input IN3 If the position limit s...

Страница 5: ...g on the product type if the supply voltage drops below 8 4 8 2V the module turns off automatically and it turns back on when the supply voltage is at least 11 2 11 4V The minimum supply voltage level...

Страница 6: ...tput OUT1 should be connected to input IN3 If two gates are controlled the position limit switch of the gate controlled by output OUT2 should be connected to input IN4 For control modes 3 4 and 5 the...

Страница 7: ...d 5 Wiring example for control mode 3 The example shows wiring of inputs IN1 and IN2 when configured to normally open and when inputs IN3 and IN4 are configured to normally closed The example shows wi...

Страница 8: ...to open the socket 3 slide the SIM card into the opened part with the contacts facing down as shown in the figure Close back the opened part together with the SIM card Press down carefully the metalli...

Страница 9: ...to the module Check the wires to be connected as instructed in the wiring diagram You can power up the device 9 30 VAC DC Make sure that the power source is sufficient for the operation of the Gate C...

Страница 10: ...of the installation wizard to complete the installation The latest version of the programming software can be downloaded from the manufacturer s website https tell hu en products gsm automation gsm g...

Страница 11: ...d the event log can be downloaded and status information is also available 4 3 Configuring by computer over the Internet For connecting via the Internet the SIM card installed into the Gate Control Pr...

Страница 12: ...entifier window then select the Password for remote programming option in the Client identifier section and enter the new password here The software will ask for this password and the user name of the...

Страница 13: ...dentifiers button In the SIM identifier editor window you can add new SIM identifiers delete existing ones and change the name and identifier number of existing ones Adding a new SIM identifier To add...

Страница 14: ...e Internet green After connecting successfully the settings can be read and changed the event log can be downloaded and the status information can be viewed just like when connected via USB Of course...

Страница 15: ...uptime since the last GSM network connection IP uptime the uptime since the last internet connection GSM operator the name of the GSM operator used actually GSM signal actual GSM signal level Lowest...

Страница 16: ...ent log to file in CSV format Reading the event log from the module When reading the event log you can specify by filtering options the period and event type you wish to download It is also possible t...

Страница 17: ...on Create full system backup You can create a full system backup after clicking on this button The full system backup includes all the settings as well as users database client identifiers templates a...

Страница 18: ...ation for backup GSM calls and for SMS sending during the smart device registration process PIN code if you wish to use PIN code management enter here the PIN code of the SIM card installed into the m...

Страница 19: ...rol call by calling back the given number Callback option can be enabled separately for each user With this setting it can be configured how long the system should ring the user s phone when calling b...

Страница 20: ...the image transfer mode supported by the IP camera Stream video continuous content Picture still picture This function works only with cameras that support the ONVIF standard The manufacturer does not...

Страница 21: ...rnet access and the outgoing e mail account settings Type open the drop down menu and select the report types which you wish to receive by e mail Event log a full event log can be sent daily or weekly...

Страница 22: ...more messages within 24 hours than the number entered here After 24 hours the counter resets automatically thus thereafter incoming messages will be forwarded up to the configured limit number In case...

Страница 23: ...input IN1 IN4 is shorted to V terminal DC power negative Special input functions available when using the system with the smartphone application IN1 doorbell notification function via Push notificatio...

Страница 24: ...SMS and or e mail upon activating the given input Attention The following characters should not be used Position limit switch OUT1 enabling on input IN3 the gate position limit switch installed on th...

Страница 25: ...ing gate A B OUT2 impulse length seconds opening gate B Selective control of outputs OUT1 and OUT2 by using caller identification and by blocking caller ID sending If the caller sends the caller ID ou...

Страница 26: ...for X seconds then after W seconds output OUT2 gives open contact for Y seconds then after 1 second output OUT1 gives again closed contact for Z seconds This control mode can be used if the gate cont...

Страница 27: ...same user during opening process or opened period during X Y period The gate will close when a third call is received from the same user or a new call from a different user This function cannot be use...

Страница 28: ...ed or select it by clicking on the element and then click on the Edit button Enter the element s custom name in the dialog window then click on the Write button Other options export custom names to CS...

Страница 29: ...cessary to write them into the module using the Write button erasing the automatic timed control templates deletes all existing automatic timed control templates from the system erasing the access tem...

Страница 30: ...ays and user custom rules When this option is selected anyone who sends the caller ID may control the system If the user blocks the caller ID the request for control will be rejected except when contr...

Страница 31: ...control modes in case of using control mode 1 or 2 output OUT1 and output OUT2 give permanent closed contact during the interval between the time configured at Open and Close options The automatic ti...

Страница 32: ...e by 1 minute but up to 3 messages only Available options read timed control templates from the module add new timed control template edit the selected timed control template delete the selected timed...

Страница 33: ...ch user when they can access and control the system Out of the configured entry periods the system rejects the given user s request for control except if this is not overridden by global rule or custo...

Страница 34: ...in the configured entry periods and is denied out of the periods If you wish to prohibit entry for a certain day then enter value 00 00 into both time fields of the given day In the Holiday section yo...

Страница 35: ...e g 3630 The system accepts maximum 20 digits Accepted characters are 0 9 only Permission you can choose out of three permission levels User can only control the system Admin can control the system an...

Страница 36: ...w will receive Technical or device error messages by Push notification when input IN2 is activated If this option is disabled then the smart devices of the given user will not receive technical error...

Страница 37: ...y is prohibited for all users except this user who has to work Custom rules are only overridden by the global rule which can be configured in the Admin functions menu Custom rule settings Type None no...

Страница 38: ...r Super admin permission then add the client identifier to this user To add a new client identifier manually click the one New button enter the name of the smart device in the Name section of the Clie...

Страница 39: ...eriod configured in the Holiday section of the access templates and will be prohibited out of the period The entry permission can be overridden with custom or global rules For the automatic timed cont...

Страница 40: ...update the phone number in the settings After replacing the SIM card it is necessary to delete the given module s control button in all smartphone applications assigned and the control button should b...

Отзывы: