6  Replacing the SIM card 

If the “

Online mode

” is enabled in the settings, the 

Gate Control Pro

 module is identified in 

the  system    by  the  identification  number  of  the  SIM  installed  into  the  module,  therefore 
replacing the SIM card affects the operation of the system. If it is necessary to replace the 
SIM card for any reason, please follow the instructions below: 

  Power down the module, replace the SIM card and power up the module. 

 

If the module’s phone number has also changed by replacing the SIM card, update 
the phone number in the settings. 

 

After  replacing  the  SIM  card  it  is  necessary  to  delete  the  given  module’s  control 
button  in  all  smartphone  applications  assigned,  and  the  control  button  should  be 
added  again  by  assigning  the  smartphone  applications  again  to  the 

Gate  Control 

Pro

 module. 

If  the 

Online  mode

”  is  disabled  and  the  module  is  not  used  with  the  smartphone 

application, to replace the SIM card just power down the module, replace the SIM card and 
power up the module again. 

7  Contents of the package 

 

GSM Gate Control Pro

 + system terminal 

  GSM 900/1800 MHz antenna 

  Installation and application manual 

 

Smartphone application user’s manual 

  Smartphone application quick start guide 

  Warranty card 

Содержание GSM Gate Control Pro 1000

Страница 1: ...caller identification 5 different control modes 4 NO NC inputs 2 NO relay outputs 50 configurable access templates Configurable holidays Automatic timed controls 20 and 1000 user variant Reports the s...

Страница 2: ...nfiguring by computer via USB 11 4 3 Configuring by computer over the Internet 11 4 3 1 Adding a client identifier for the programming software 12 4 3 2 Managing SIM identifiers 13 4 3 3 Steps of remo...

Страница 3: ...ent permissions and access periods as well as custom access rules can be assigned The access periods can be configured by access templates which can be assigned to users The system will accept control...

Страница 4: ...while the position limit switch of gate B should be connected to input IN4 In case of control modes 3 4 and 5 the gate s position limit switch should be connected to input IN3 If the position limit s...

Страница 5: ...g on the product type if the supply voltage drops below 8 4 8 2V the module turns off automatically and it turns back on when the supply voltage is at least 11 2 11 4V The minimum supply voltage level...

Страница 6: ...tput OUT1 should be connected to input IN3 If two gates are controlled the position limit switch of the gate controlled by output OUT2 should be connected to input IN4 For control modes 3 4 and 5 the...

Страница 7: ...d 5 Wiring example for control mode 3 The example shows wiring of inputs IN1 and IN2 when configured to normally open and when inputs IN3 and IN4 are configured to normally closed The example shows wi...

Страница 8: ...to open the socket 3 slide the SIM card into the opened part with the contacts facing down as shown in the figure Close back the opened part together with the SIM card Press down carefully the metalli...

Страница 9: ...to the module Check the wires to be connected as instructed in the wiring diagram You can power up the device 9 30 VAC DC Make sure that the power source is sufficient for the operation of the Gate C...

Страница 10: ...of the installation wizard to complete the installation The latest version of the programming software can be downloaded from the manufacturer s website https tell hu en products gsm automation gsm g...

Страница 11: ...d the event log can be downloaded and status information is also available 4 3 Configuring by computer over the Internet For connecting via the Internet the SIM card installed into the Gate Control Pr...

Страница 12: ...entifier window then select the Password for remote programming option in the Client identifier section and enter the new password here The software will ask for this password and the user name of the...

Страница 13: ...dentifiers button In the SIM identifier editor window you can add new SIM identifiers delete existing ones and change the name and identifier number of existing ones Adding a new SIM identifier To add...

Страница 14: ...e Internet green After connecting successfully the settings can be read and changed the event log can be downloaded and the status information can be viewed just like when connected via USB Of course...

Страница 15: ...uptime since the last GSM network connection IP uptime the uptime since the last internet connection GSM operator the name of the GSM operator used actually GSM signal actual GSM signal level Lowest...

Страница 16: ...ent log to file in CSV format Reading the event log from the module When reading the event log you can specify by filtering options the period and event type you wish to download It is also possible t...

Страница 17: ...on Create full system backup You can create a full system backup after clicking on this button The full system backup includes all the settings as well as users database client identifiers templates a...

Страница 18: ...ation for backup GSM calls and for SMS sending during the smart device registration process PIN code if you wish to use PIN code management enter here the PIN code of the SIM card installed into the m...

Страница 19: ...rol call by calling back the given number Callback option can be enabled separately for each user With this setting it can be configured how long the system should ring the user s phone when calling b...

Страница 20: ...the image transfer mode supported by the IP camera Stream video continuous content Picture still picture This function works only with cameras that support the ONVIF standard The manufacturer does not...

Страница 21: ...rnet access and the outgoing e mail account settings Type open the drop down menu and select the report types which you wish to receive by e mail Event log a full event log can be sent daily or weekly...

Страница 22: ...more messages within 24 hours than the number entered here After 24 hours the counter resets automatically thus thereafter incoming messages will be forwarded up to the configured limit number In case...

Страница 23: ...input IN1 IN4 is shorted to V terminal DC power negative Special input functions available when using the system with the smartphone application IN1 doorbell notification function via Push notificatio...

Страница 24: ...SMS and or e mail upon activating the given input Attention The following characters should not be used Position limit switch OUT1 enabling on input IN3 the gate position limit switch installed on th...

Страница 25: ...ing gate A B OUT2 impulse length seconds opening gate B Selective control of outputs OUT1 and OUT2 by using caller identification and by blocking caller ID sending If the caller sends the caller ID ou...

Страница 26: ...for X seconds then after W seconds output OUT2 gives open contact for Y seconds then after 1 second output OUT1 gives again closed contact for Z seconds This control mode can be used if the gate cont...

Страница 27: ...same user during opening process or opened period during X Y period The gate will close when a third call is received from the same user or a new call from a different user This function cannot be use...

Страница 28: ...ed or select it by clicking on the element and then click on the Edit button Enter the element s custom name in the dialog window then click on the Write button Other options export custom names to CS...

Страница 29: ...cessary to write them into the module using the Write button erasing the automatic timed control templates deletes all existing automatic timed control templates from the system erasing the access tem...

Страница 30: ...ays and user custom rules When this option is selected anyone who sends the caller ID may control the system If the user blocks the caller ID the request for control will be rejected except when contr...

Страница 31: ...control modes in case of using control mode 1 or 2 output OUT1 and output OUT2 give permanent closed contact during the interval between the time configured at Open and Close options The automatic ti...

Страница 32: ...e by 1 minute but up to 3 messages only Available options read timed control templates from the module add new timed control template edit the selected timed control template delete the selected timed...

Страница 33: ...ch user when they can access and control the system Out of the configured entry periods the system rejects the given user s request for control except if this is not overridden by global rule or custo...

Страница 34: ...in the configured entry periods and is denied out of the periods If you wish to prohibit entry for a certain day then enter value 00 00 into both time fields of the given day In the Holiday section yo...

Страница 35: ...e g 3630 The system accepts maximum 20 digits Accepted characters are 0 9 only Permission you can choose out of three permission levels User can only control the system Admin can control the system an...

Страница 36: ...w will receive Technical or device error messages by Push notification when input IN2 is activated If this option is disabled then the smart devices of the given user will not receive technical error...

Страница 37: ...y is prohibited for all users except this user who has to work Custom rules are only overridden by the global rule which can be configured in the Admin functions menu Custom rule settings Type None no...

Страница 38: ...r Super admin permission then add the client identifier to this user To add a new client identifier manually click the one New button enter the name of the smart device in the Name section of the Clie...

Страница 39: ...eriod configured in the Holiday section of the access templates and will be prohibited out of the period The entry permission can be overridden with custom or global rules For the automatic timed cont...

Страница 40: ...update the phone number in the settings After replacing the SIM card it is necessary to delete the given module s control button in all smartphone applications assigned and the control button should b...

Отзывы: