![tell GSM Gate Control Pro 1000 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/tell/gsm-gate-control-pro-1000/gsm-gate-control-pro-1000_installation-and-application-manual_1083871011.webp)
11
4.2 Configuring by computer via USB
To start programming the
Gate Control Pro
module, follow the instructions below:
Open the
Gate Control Pro
programming software.
Power up the
Gate Control Pro
module and connect it to the computer using a USB
A-B cable.
The software connects to the
Gate Control Pro
module using standard HID driver
which is integrated in Windows operating systems, thus there is no need to install
special USB drivers. When the
Gate Control Pro
module is connected to USB for the
very first time, the Windows operating system installs the drivers automatically.
The system does not use a security password for connecting via USB. After
connecting the USB cable, the software connects automatically to the
Gate Control
Pro
module.
Connection status is indicated by the USB status icon placed on the “
Connection
” tab:
: USB disconnected (grey)
: connected via USB (green)
After the connection is established, the settings can be read and changed, the event
log can be downloaded and status information is also available.
4.3 Configuring by computer over the Internet
For connecting via the Internet, the SIM card installed into the
Gate Control Pro
module should have Internet service and should also use public APN.
To connect to the module via the Internet, an intermediary server is also necessary, where
both the programming software and the module connects, through which this way the
connection can be established between the programming software and the module. The
manufacturer of the product provides a server for this purpose available 24 hours a day,
which can be used free of charge.
Remote programming by computer can be done using the
Gate Control Pro
programming
software (desktop application). In case of remote access, the programming software
connects to the
Gate Control Pro
module as a client application using user name and
password, therefore it is necessary to add beforehand a new client identifier via USB
connection and assign this identifier to the user whom you wish to give remote access.
Thereby practically any user may get remote access according to its permission level.