![tell GSM Gate Control Pro 1000 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/tell/gsm-gate-control-pro-1000/gsm-gate-control-pro-1000_installation-and-application-manual_1083871022.webp)
22
5.3.9 Miscellaneous settings
Installer’s e-mail address
: the system sends notifications about version updates to the e-
mail address specified here. If you wish to use the e-mailing services of the system, it is
necessary to configure the internet access and the outgoing e-mail account settings.
SMS forwarding phone number
: the system forwards the messages received by its SIM
card to the phone number entered here (e.g. balance information received from the GSM
service provider in case of pre-pay card). The system deletes the received message
automatically after forwarding.
SMS sending limit per day
: with this setting you can limit the number of SMS messages to
be sent upon activating the inputs. The system does not allow sending more messages
within 24 hours than the number entered here. After 24 hours the counter resets
automatically, thus thereafter messages can be sent again upon activating the inputs, up to
the configured limit number. In case of entering “0” value, SMS sending will be disabled.
SMS forwarding limit per day
: with this setting you can limit the number of SMS messages
to be forwarded. The system does not allow forwarding more messages within 24 hours
than the number entered here. After 24 hours the counter resets automatically, thus
thereafter incoming messages will be forwarded, up to the configured limit number. In case
of entering “0” value, SMS forwarding will be disabled, thus incoming SMS messages will
not be forwarded, but deleted.
Attention! After reaching the configured limit, but still before resetting the counter the system
deletes all incoming messages without forwarding!
Time zone
: select the time zone according to the installation location. The system adjusts
the system time according to the time zone setting. If the setting is incorrect and therefore
the system times is different than the local time, this affects the operation since the access
templates, the rules and the automatic timed controls are all based on the system time.
Automated daylight saving: the system includes automatic daylight saving management
based on the configured time zone.
Push notification language
: in the drop-down menu you can select the language to be
used on the assigned smart devices to display Push notification messages sent by the
system.
Date format
: you can select out of two date formats:
- Hungarian format: YYYY.MM.DD hh:mm:ss
- International format: DD/MM/YYYY hh:mm:ss
First day of the week
: to support international usage, the day the week starts on can be
selected.