Control mode 4
OUT1=N.O. (normally open)
OUT2=N.O. (normally open)
X
= OUT1 impulse length (seconds) => gate opening
Y
= keeping the gate open (seconds)
Z
= OUT2 impulse length (seconds) => gate closing
Starting a control process using caller identification. Outputs OUT1 and OUT2 provide
opened contact by default. When calling, output OUT1 gives closed contact for
X
seconds,
then after
Y
seconds output OUT2 gives closed contact for
Z
seconds. This control mode
can be used when the gate controller panel expects the opening and closing control
impulses on two different inputs (impulse on an input opens the gate, impulse on another
input closes the gate).
Keep the gate open permanently upon quick recall:
if enabled, the gate remains open
permanently (
Y
=infinite) after receiving a second call from the same user during opening
process or opened period (during
X
+
Y
period). The gate will close when a third call is
received from the same user or a new call from a
different user
. This function cannot be
used with hidden caller ID.
Control mode 5
OUT1=N.O. (normally open)
OUT2=N.O. (normally open)
X
= OUT1 impulse length (seconds) => gate opening
Z
= OUT2 impulse length (seconds) => gate closing
Opening and closing by separate calls. Outputs OUT1 and OUT2 provide opened contact by
default. Output OUT1 gives closed contact for
X
seconds upon the first call, then upon the
second call from the same user output OUT2 gives closed contact for
Z
seconds. This
control mode can be used when the gate controller panel expects the opening and closing
control impulses on the same input or on two different inputs. If opening and closing control
is done on the same input, outputs OUT1 and OUT2 should be connected in parallel to the
input to be controlled. This control mode cannot be used with hidden caller ID.