Output control permissions
:
OUT1, OUT2
: enable/disable permission for selective control of outputs in the
smartphone applications of the given user. It can be configured for each user
separately, which output to be controllable from the smartphone applications (output
OUT1, OUT2 or both). This option is only available in control modes 1 and 2.
Output control by call
:
OUT1, OUT2
: enable/disable selective control of outputs by call. It can be configured for
each user separately, which output to be controlled by call, using caller identification:
output OUT1, OUT2 or both at the same time. This setting also refers to controls
initiated using the smartphone application by backup phone call, when controlling over
the Internet fails due to a connection error. Unfortunately from a call it cannot be
determined which output the user would like to control, therefore it should be configured
at this option in advance, which output (or both at the same time) to be controlled by call
in such case. This option is only available in control modes 1 and 2.
Custom rule
: the access templates assigned to the user can be overridden by the custom
rule. This function is useful when the entry permission of the given user has to be different in
some manner from the access templates (e.g. at a company any user may control the
system on a certain day except this user, because of being on holiday, etc., or even on a
weekend day, entry is prohibited for all users, except this user who has to work).
Custom rules are only overridden by the global rule, which can be configured in the
“
Admin functions
” menu.
Custom rule settings:
Type
:
-
None
: no custom rule configured
-
Allow
: can control the system in the specified period against the prohibition by access
templates
-
Deny
: control of the system is denied in the specified period against the permission by
the access templates
Authorizer
: here the identifier of the admin or super admin is shown, who has configured
the custom rule for the given user. This is filled in automatically by the system. If the
custom
rule has been configured using the programming software, then “
Software
” will
be shown here.
From
: enter the beginning of the custom rule validity period. You can select the date and
enter the time in the calendar after opening the drop-down menu.
Until
: enter the end of the custom rule validity period. You can select the date and enter
the time in the calendar after opening the drop-down menu.
Client identifiers
Here you can add and manage identifiers of client devices and applications connecting to
the
Gate Control Pro
module (smart devices, remote access over the internet for the
programming software).
The maximum number of client identifiers supported is 2000, which can be distributed
arbitrarily between the registered uses. These may be smartphones, tablets etc., on which
the
Gate Control
smartphone application has been installed, or the programming software
for remote access). The smart devices assigned to given user automatically inherit the
permissions and settings of the given user.