xE922-3GR Hardware User Guide
1VV0301272
Rev.0.8 2017-01-05
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved.
Page 101 of 112
Profile Feature
Pb-Free Assembly
Average ramp-up rate (T
L
to T
P
)
3°C/second max
Preheat
–
Temperature Min (Tsmin)
–
Temperature Max (Tsmax)
–
Time (min to max) (ts)
150°C
200°C
60-180 seconds
Tsmax to TL
–
Ramp-up Rate
3°C/second max
Time maintained above:
–
Temperature (TL)
–
Time (tL)
217°C
60-150 seconds
Peak Temperature (Tp)
245 +0/-5°C
Time within 5°C of actual Peak
Temperature (tp)
10-30 seconds
Ramp-down Rate
6°C/second max.
Time 25°C to Peak Temperature
8 minutes max.
NOTE:
All temperatures refer to topside of the package, measured on the package body surface.
WARNING:
The xE922-3GR module withstands one reflow process only.