REMOTE CONTROL
89
Parameter Setting
Press the System button followed by pressing the
F1 (Interface) button to select the target port: F1
(RS-232). The setting of baud rate will appear
automatically, please then choose desired setting.
Display
The parameter information of RS-232 will appear
on LCD. Refer to the description below:
8 --->data bit 8bit
N --->no parity bit
1 --->stop bit 1bit
N --->no flow control bit
Function check
Perform the following query:
*IDN?
The unit will return the manufacturer, model,
serial number and software version.
TELEDYNE, T3PS33203P, SN: xxxxxxxx, Vx.xx
Disable Remote
Control Mode
Send a remote command Locall from the PC.
Long-press the F6 (unlock) key on the front
panel.
Note
RS-232 is Not hot-plug device. Please proceed to the
connection procedure under the power-off state.
USB
Description
T3PSX3200P series can be connected via USB
using the USB Communications Device (CDC)
class.
Interface
Rear panel USB slave port.