T3PSX3200P Series User Manual
142
Example
:SEQUence2:PARAmeter? 1,2
Queries 2 groups’ sequence parameters from the
1st group for CH2.
:SEQUence[1|2]:STARt <value>
Description
Sets the sequence number for initial execution.
Parameter
<value> Integer 0 - 2047
Example
:SEQUence2:STARt 10
Sets the CH2 sequence output to start from the
group 11.
:SEQUence[1|2]:STARt?
Description
Queries the sequence number for initial execution
of the channel sequence output.
Example
:SEQUence2:STARt?
Returns the initial sequence number of CH2
sequence output.
:SEQUence[1|2] [:STATe] {ON|OFF}
Description
Enable or disable sequence function.
Enabling the sequence will change state of
channel output, make sure the changed output
state will Not impact the device connected with
power before enabling. Sequence output is
activated only when both sequence and channel
output are enabled. To modify parameter is Not
available when sequence is being enabled. For
multi-channel model, change the active channel
and set parameter of selected channel. It is Not
allowed to enable sequence and delay
simultaneously.
Содержание T3PS13206P
Страница 1: ... ...
Страница 106: ...T3PSX3200P Series User Manual 106 Register Commands OPC 187 OPC 187 ...
Страница 177: ...REMOTE CONTROL 177 Example SAV 1 Recalls the setting stored in memory 2 STATE02 ...
Страница 185: ...REMOTE CONTROL 185 Example STB Returns 81 if the status byte register is set to 0101 0001 ...
Страница 196: ...T3PSX3200P Series User Manual 196 Between chassis and DC power cord 30MΩ or above DC 500V ...
Страница 197: ... 0 0 0 1 2 3 4 5 6 7 8 8 9 3 3 3 45 6 990 0 0 9 0 0 0 9 0 0 0 0 9 7 7 88 8 1 931711 RevB ...