Teledyne API - T300/T300M and M300E/EM PN 04906H (DCN5840)
APPENDIX A-1: Software Menu Trees, Revision L.8
A-7
DISPLAY
SEQUENCE
CONFIGURATION
ANALOG
OUTPUT
SETUP
PASS
DAS RNGE
CLK
MORE
ACAL
CFG
SAMPLE
COMM
VARS
DIAG
NEXT
PREV
SIGNAL I/
O
ANALOG
CONFIGURATION
DARK
CALIBRATION
ELECTRICAL
TEST
FLOW
CALIBRATION
Press
ENTR
to start test
Press
ENTR
to start test
Press
ENTR
to start test
ENTER PASSWORD: 818
EDIT
PRNT
DEL
INS
NEXT
PREV
NO
YES
Cycles through list of
already programmed
display sequences
NEXT
PREV
CO
CO2
4
O2
4
DISPLAY DATA
DISPLAY DURATION
ENTR
NEXT
PREV
EXT ZERO CAL
EXT SPAN CAL
REMOTE RANGE HI
SYNC OK
MAINT MODE
LANG2 SELECT
SAMPLE LED
CAL LED
FAULT LED
AUDIBLE BEEPER
ELEC TEST
DARK CAL
ST SYSTEM OK
ST CONC VALID
ST HIGH RANGE
ST ZERO CAL
ST SPAN CAL
ST DIAG MODE
ST CONC ALARM 1
5
ST CONC ALARM 2
5
SET AUTO REF
5
SET CO2 CAL
4
SET O2 CAL
4
ST SYSTEM OK2
RELAY WATCHDOG
WHEEL HTR
SENCH HTR
O2 CELL HEATER
4
CAL VALVE
SPAN VALVE
ZERO SCRUB VALVE
IR SOURCE ON
30 INTERNAL ANALOG
to
VOLTAGE SIGNALS
55
(see Appendix A)
ON
OFF
CAL
EDIT
SET>
<SET
AOUTS CALIBRATED
DATA OUT 1
1
DATA OUT 2
1
DATA OUT 3
1
DATA OUT 4
1
AIN CALIBRATED
10V
CURR
5V
1V
0.1V
ON
OFF
ON
OFF
CAL
2
Auto Cal
Sets time lapse
between data updates
on selected output
Sets the scale
width of the
reporting range.
RANGE OVER
RANGE
CALIBRATED
OUTPUT
DATA
SCALE
UPDATE
Cycles through
the list of iDAS
data types.
RANGE
OFFSET
2
AUTO
2
CAL
Sets the
degree of
offset
ON
OFF
U100
UP10
UP
DOWN
DN10
D100
Manual Cal
3
1
Correspond to analog Output A1 – A4 on back of
analyzer
2
Only appears if one of the voltage ranges is selected.
3
Manual adjustment menu only appears if either the
Auto Cal feature is
OFF
or the range is set for
CURR
ent.
4
Only appears if the related sensor option is installed.
5
Only appears in T300M and M300EM
PRESSURE
CALIBRATION
Press
ENTR
to start test
Figure A-6: DIAG Menu
06864B DCN6314
Содержание T300
Страница 2: ......
Страница 4: ...Teledyne API Model T300 T300M CO Analyzer ii This page intentionally left blank 06864B DCN6314 ...
Страница 8: ...Teledyne API Model T300 T300M CO Analyzer vi This page intentionally left blank 06864B DCN6314 ...
Страница 12: ...Teledyne API Model T300 T300M CO Analyzer x This page intentionally left blank 06864B DCN6314 ...
Страница 25: ...23 PART I GENERAL INFORMATION 06864B DCN6314 ...
Страница 26: ...24 06864B DCN6314 ...
Страница 88: ...Getting Started Teledyne API Model T300 T300M CO Analyzer 86 This page intentionally left blank 06864B DCN6314 ...
Страница 89: ...87 PART II OPERATING INSTRUCTIONS 06864B DCN6314 ...
Страница 90: ...Getting Started Teledyne API Model T300 T300M CO Analyzer 88 06864B DCN6314 ...
Страница 144: ...Setup Menu Teledyne API Model T300 T300M CO Analyzer 142 This page intentionally left blank 06864B DCN6314 ...
Страница 198: ...Remote Operation Teledyne API Model T300 T300M CO Analyzer 196 This page intentionally left blank 06864B DCN6314 ...
Страница 243: ...241 PART III TECHNICAL INFORMATION 06864B DCN6314 ...
Страница 244: ...06864B DCN6314 ...
Страница 245: ...243 06864B DCN6314 ...
Страница 246: ...06864B DCN6314 ...
Страница 346: ...INDEX Teledyne API Model T300 T300M CO Analyzer 344 This page intentionally left blank 06864B DCN6314 ...
Страница 386: ...This page intentionally left blank B 2 06864B DCN6314 ...
Страница 395: ...APPENDIX D Wire List and Electronic Schematics 06864B DCN6314 D 1 ...
Страница 396: ...This page intentionally left blank D 2 06864B DCN6314 ...
Страница 400: ...This page intentionally left blank D 6 06864B DCN6314 ...
Страница 401: ...06864B DCN6314 D 7 ...