RiverPro and RioPro ADCP Guide
October 2017
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Page 81
Command Summary
gives a summary of the RiverPro/RioPro input commands, their format, and a brief description
of the parameters they control, and the factory default command settings.
When newer firmware versions are released, some commands may be modified or added.
Read the README file on the upgrade disk or check TRDI’s web site for the latest changes.
Table 10:
RiverPro/RioPro Input Command Summary
Command Default
Description
?
Shows command menu (deploy or system)
<BREAK> End
Interrupts or wakes up RiverPro/RioPro and loads last settings used
Y
Display banner
OI
Install New Feature
OL
Display Feature List
BP 1
Number of BT Pings in ensemble [0-999]
BX 00500
Max Depth (dm) [10-65535 dm]
CA0
Communication Timeout (0=Off,10-65536 sec)
CB811
Serial port control (baud rate/parity/stop bits)
CF 11111
Set Ctrl Flags {e;p;b;s;*}
CK
Save Command Parameters to Flash as user defaults
CR
Restore command defaults (0=user, 1=factory)
CS
Start pinging
CSTATE
Pinging State Query
CSTOP
Stop pinging
CT 0
Turnkey (0 = OFF, 1 = ON)
CW
Output the Last Stored Ensemble
CZ
Put the system to sleep
EA +00000
Heading alignment (-179.99 to 180.00 degrees)
EB +00000
Heading bias (-179.99 to 180.00 degrees)
EC 1485
Speed of Sound (1400 to 1600 m/s)
ED 00000 -
Transducer Depth (0 to 65535 dm)
EH 00000 -
Heading (000.00 to 359.99 degrees)
EP +00000
Pitch (-70.00 to +70.00 degrees)
ER +00000
Roll (-70.00 to +70.00 degrees)
ES 00
Salinity (0 to 45)
ET 2100
Temperature (-5.00 to +35.00 degrees C)
EU 0
System Orientation 1=up,0=down
EX 00000
Coordinate Transformation (Xform:Type; Tilts; 3Bm; Map)
EZ 1011101
Sensor Source (C;D;H;P;R;S;T)