RiverPro and RioPro ADCP Guide
October 2017
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Page 103
EZ – Sensor Source
Purpose
Selects the source of environmental sensor data.
Format
EZcdhprst
Default
EZ1011101
Recommended Setting
. The default setting for this command is recommended for most applications.
Range
Firmware switches (see description)
Description
Setting the EZ-command firmware switches tells the RiverPro/RioPro to use data from a
manual setting or from an associated sensor. When a switch value is non-zero, the
RiverPro/RioPro overrides the manual E-command setting and uses data from the appro-
priate sensor. If no sensor is available, the RiverPro/RioPro defaults to the manual E-
command setting. The following table shows how to interpret the sensor source switch
settings.
Table 15:
Sensor Source Switch Settings
Field
Value = 0
Value = 1
c
Speed Of Sound
Manual EC
Calculate using ED, ES, and ET
d
Depth
Manual ED
N/A
h
Heading
Manual EH
Internal Heading Sensor
p
Pitch (Tilt 1)
Manual EP
Internal Pitch Sensor
r
Roll (Tilt 2)
Manual ER
Internal Roll Sensor
s
Salinity
Manual ES
N/A
t
Temperature
Manual ET
Internal Transducer Sensor
Example
EZ1011101 means calculate speed of sound from readings, use pressure sensor, trans-