![Tele Radio T24-01 Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/tele-radio/t24-01/t24-01_installation-instructions-manual_1079620083.webp)
Installation instructions
│
T24
│
Annex A: List of errors and error messages
Event code
Event description
Category
SafetyCpuInBootloader (1140)
[ Safety CPU is in
bootloader, no valid firmware
loaded ]
2hw (sw
needs to
be
flashed
again)
SafetyCpuNoResponseToCpuQuery (1141)
[ Safety CPU did not respond
to CPU query ]
1
SafetyCpuNoResponseToVersionQuery
(1142)
[ Safety CPU did not respond
to version query ]
1
SafetyCpuInvalidResponsToCpuQuery
(1143)
[ Safety CPU responded with
malformed response to CPU
query ]
1
SafetyCpuInvalidResponsToVersionQuery
(1144)
[ Safety CPU responded with
malformed response to version
query ]
1
SafetyCpuInvalidSwVersion (1145)
[ Safety CPU has invalid SW
version ]
1
SafetyCpuFailedToStartCommunication
(1146)
[ Safety CPU failed to start
communication, entering
trabus level 2X ]
1
SafetyCpuFailedToStopCommunication
(1147)
[ Safety CPU failed to stop
communication, leaving trabus
level 2X ]
1
SafetyCpuLostContact (1148)
[ Safety CPU seems dead, lost
contact when in state
\"running\" ]
1
SafetyCpuFailedCommunicationDuringStartup
(1149)
[ Safety CPU failed to enter
level 2A during startup ]
1
StopButtonDisagreementCpu1Cpu2 (1160)
[ CPU2 says stop button is
pulled when CPU1 says it is
pushed ]
2hw
StopButtonAdcError (1161)
[ The AD converter used to
measure the stop button state
is faulty ]
2hw
IM-PM-TX101-EN-v08
83