![Tele Radio T24-01 Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/tele-radio/t24-01/t24-01_installation-instructions-manual_1079620082.webp)
Installation instructions
│
T24
│
Annex A: List of errors and error messages
Event code
Event description
Category
ChargerBatterySelection (1073)
[ Battery xxxx selected for
charging ]
2
ChargingReport (1074)
[ Charging report, current
charger voltage (milli-
volts): xxxx, current battery
voltage (milli-volts): xxxx,
batSupervisionStatus: xxxxxx,
batChargingStatus: xxxxxx ]
3
ChargingErrorBadBattery (1075)
[ Battery xxxx was detected
bad during charging ]
3
ChargingAborted (1076)
[ Charging aborted before
battery xxxx was completed ]
2
ChargerBatteryRemoved (1077)
[ Battery xxxx was removed
when being charged ]
3
ChargingCompleted (1078)
[ Charging of battery xxxx
completed ]
3
ChargingQualification (1079)
[ Entering qualification
charging for battery xxxx ]
2
ChargingStarted (1080)
[ Charging started for
battery xxxx ]
3
BatteryInstalled (1081)
[ Battery xxxx detected as
installed ]
3
BatteryRemoved (1082)
[ Battery xxxx was removed ]
3
UnknownEventFromCPU3 (1100)
[ Unknown event from CPU3:
xxxx ]
1
InvalidEventArgsLen (1110)
[ Invalid CPU3 to CPU1 event
argument length. Event: xxxx,
argument length: xxxx ]
1
ConfigurationOfCC2520Failed (1120)
[ Configuration of radio chip
failed. HW-problem ? ]
1
ReconfigurationOfCC2520Failed (1121)
[ Reconfiguration of radio
chip, most likely due to ESD,
failed too many times ]
1
InvalidProductionData (1130)
[ No valid production data in
unit ]
2hw
82