Save and Recall Information
After the network connection has been established, do the following:
1. Push the front-panel Save/Recall Menu button.
2. Push the bottom-bezel
File Utilities
item and, from the resulting side menu, select
– more – 1 of 2
. Then select
Mount
.
3. From the resulting side menu, set the following:
Setting
Description
Drive Letter
Select from I: to Z:
Server Name or IP Address
Use a USB keyboard or the on-screen interface to enter the server name or IP
address.
Path
Use a USB keyboard or the on-screen interface to enter the shared
fi
le path.
For example, to mount an MS Windows PC directory named “C:\Example”, enter
“C$\Example”. The dollar sign enables sharing. No colon is needed.
User Name
If necessary, use a USB keyboard or the on-screen interface to enter the user name.
User Password
If necessary, use a USB keyboard or the on-screen interface to enter the user
password. The oscilloscope only displays “*”’s as you type the password. They are
erased from the screen after
OK Accept
is pushed.
NOTE.
Ensure that
fi
le sharing is enabled for the network location.
4. Push
OK Accept
.
NOTE.
To unmount a network drive, push the front panel Save/Recall
Menu
button, the lower-bezel menu
File Utilities
, the
side-menu
– more – 1 of 2
, and
Unmount
items.
NOTE.
Any network locations that were mounted when the oscilloscope was powered down will be automatically remounted
when the oscilloscope is powered up. Unmount any network location that you do not want to automatically remount
on power up.
Printing a Hard Copy
To print an image of what appears on the oscilloscope screen, do the following procedure.
Connect a Printer to Your Oscilloscope
Connect a non-PictBridge printer to a USB port on the rear or front panel of the oscilloscope. Alternatively, connect a
PictBridge printer to the USB device port on the rear panel, or hook up a networked printer through the Ethernet port.
NOTE.
Refer to the www.tektronix.com/printer_setup Web page for a list of compatible printers.
MDO4000 Series Oscilloscopes User Manual
171
Содержание MDO4054-3
Страница 2: ...x MDO4000 Series Mixed Domain Oscilloscopes ZZZ User Manual P071291300 071 2913 00...
Страница 3: ......
Страница 4: ...MDO4000 Series Mixed Domain Oscilloscopes ZZZ User Manual xx www tektronix com 071 2913 00...
Страница 11: ...Table of Contents iv MDO4000 Series Oscilloscopes User Manual...
Страница 19: ...Preface xii MDO4000 Series Oscilloscopes User Manual...
Страница 215: ...Appendix C P6616 General Purpose Logic Probe Information 196 MDO4000 Series Oscilloscopes User Manual...