Performance Check Procedure— 2230 Service
3. Check External Clock
a. Set:
CH 1 VOLTS/DIV
1 V
A SEC/DIV
1 ms
b. Connect the Pulse Generator high-amplitude output
via a 50 0 cable and a 50 Q termination to CH 1 OR X
input connector.
c. Set the generator to produce a 1 kHz, 5-division
display.
d. Disconnect the cable from the CH 1 OR X input con
nector and connect it to the BNC male-to-tip plug via
BNC female to BNC female connector.
e. Insert the BNC male-to-tip plug signal lead and
ground lead into pin 1 and pin 9 respectively of the X-Y
Plotter connector.
f. Set the A SEC/DIV switch to 0.1 sec.
g. Connect the Calibration Generator high-amplitude
output via a 50 n cable and a 50 Q termination to CH 1
OR X input connector.
h. Set the generator to produce a 100 Hz, 5-division
display.
i. Set:
A SEC/DIV
EXT CLK
STORE/NON STORE
STORE (button in)
J. CHECK—The 100 Hz signal is displayed on the
screen and updated.
k. Set the SAVE/CONTINUE switch to SAVE (button
in).
l
. CHECK—The display is saved.
m. Disconnect the test equipment from the instrument.
4. Check X-Y Plotter
a.
Connect the digital voltmeter low lead to either
chassis ground or pin 9 (signal ground) of the X-Y Plotter
connector. Connect the volts lead to pin 3 (X Output) of
the X-Y Plotter connector.
b. Set the digital voltmeter to the 20 V scale.
C. Set the WAVEFORM REFERENCE/MENU SELECT
switch to MENU SELECT (button out).
d. Use the Menu controls to select PLOT and then ON
for GRATICULE.
NOTE
The next menu selection Is only valid if the instru
ment contains one of the communication options.
e. Use the Menu controls to select PLOT and then XY
for FORMAT.
f. Use the Menu controls to select PLOT START.
g. Press in momentarily the CURSORS button to
activate the X-Y Plotter.
NOTE
Voltage reading of the X Output will be negative left
of the center vertical graticule line and positive to the
right of the center vertical graticule line. Voltage
reading of the Y output will be negative below the
center horizontal graticule line and positive above
the center horizontal graticule line.
h. Record the voltage reading as the instrument plots
the 1st and the 10th graticule line (as the intensity spot
moves along the graticule line).
i. CHECK—The voltage difference between the 1st and
10th graticule line is between 4.5 V and 5.5 V.
J. Move the volts lead of the voltmeter from pin 3 (X
Output) to pin 5 (Y Output) of the X-Y Plotter connector.
k.
Press in momentarily the CURSORS button to
activate the X-Y Plotter.
l
. Record the voltage reading as the instrument plots
the top and the bottom of the graticule lines (as the inten
sity spot moves along the graticule line).
m. CHECK—The voltage difference between the top
and bottom graticule line is between 3.6 V and 4.4 V.
n. Disconnect the test equipment from the instrument.
4-22
REV DEC 1986
Содержание 2230
Страница 12: ...2230 Service X The 2230 Digital Storage Oscilloscope 4998 01 ...
Страница 32: ...Operating Information 2230 Service 4998 04 Figure 2 4 Power and display controls and power on indicator 2 5 ...
Страница 33: ...Operating Information 2230 Service Figure 2 5 Vertical controls and connectors 2 6 ...
Страница 48: ...Operating Information 2230 Service Figure 2 11 X Y Plotter interfacing ...
Страница 56: ...Theory of Operation 2230 Service 4999 01 3 2 Figure 3 1 Simplified block diagram ...
Страница 68: ...Operating Information 2230 Service Figure 2 11 X Y Plotter interfacing ...
Страница 76: ...Theory of Operation 2230 Service 4999 01 3 2 Figure 3 1 Simplified block diagram ...
Страница 82: ...Theory of Operation 2230 Service 510 499 9 02 Figure 3 2 Block diagram of the Channel 1 Attenuator circuit 3 8 ...
Страница 98: ...Theory of Operation 2230 Service 499 9 06 Figure 3 6 Horizontal Amplifier block diagram 3 24 ...
Страница 111: ...Theory of Operation 2230 Service 3 37 Figure 3 9 Acquisition Memory timing ...
Страница 190: ...Maintenance 2230 Service 999 14 Figure 6 3 Isolated kernel timing 6 9 ...
Страница 218: ...Maintenance 2230 Service 4999 37 Figure 6 7 Location of screws and spacers on the Storage circuit board 6 37 ...
Страница 329: ...PUT Figure 9 2 S em ico n d u cto r lea d co n fig u ratio n s ...
Страница 332: ...2230Service CHASSIS MOUNTED PARTS ...
Страница 334: ...A14 CH 1 LOGIC BOARD ...
Страница 337: ......
Страница 344: ...u sr z z o 1 ...
Страница 347: ...i n 5 a O Q q o u S a o h UJ s a b c d e f g h j k l m n ...
Страница 352: ......
Страница 355: ...WAVEFORMS FOR DIAGRAM 5 4999 83 ...
Страница 358: ...I W L U O U rc a 4 2 s ...
Страница 361: ...WAVEFORMS FOR DIAGRAM 6 S 84 ...
Страница 362: ...2230 Service TEST SCOPE TRIGGERED ON U665 PIN 8 FOR WAVEFORMS 31 THROUGH 33 ...
Страница 365: ... I I ...
Страница 366: ...A 1 6 S W E E P R EFEREN CE BOARD FIG 9 17 2230 Service Figure 9 17 A16 Sweep Reference board ...
Страница 369: ... o 0 UJU sa eg aiu c u J in su eg 5 C sis n g e s o N QO ...
Страница 371: ...Static Sensitive Devices See Maintenance Section CM I rv CD o 2230 Service ...
Страница 378: ......
Страница 384: ... I I c o C u o a 5 r O tD v j If 3 IV if I I ci if 5 3 I ...
Страница 386: ......
Страница 388: ...H K L M N 7 8 8 2 2 3 0 INPUT OUTFUT WIRING INTERCONNECT ...
Страница 392: ...W A V E F O R M S F O R D IA G R A M 14 ...
Страница 393: ...2230Service 0 0 d s t 4 9 9 9 9 5 ...
Страница 394: ...2230 Service TEST SCOPE TRIGGERED ON U911 PIN 21 FOR WAVEFORMS 64 THROUGH 69 4999 92 ...
Страница 396: ... ...
Страница 397: ...WAVEFORMS FOR DIAGRAM 15 TEST SCOPE TRIGGERED ON U9111 PIN 21 FOR WAVEFORMS 70 THROUGH 77 ...
Страница 399: ......
Страница 403: ......
Страница 404: ......
Страница 405: ......
Страница 406: ...2230 Service n CD O O i 0 s a f s s o m O F ig u re 9 5 D e ta ile d S to ra g e b lo c k diagram 4999 22 ...
Страница 409: ......
Страница 415: ...IMF PU TPR A IR TM FQ U I W A V E F O R M SF O RO IA G R A M1 5 W A V E F O R M SF O R i ...
Страница 417: ...4999 9S ...
Страница 419: ...i s 5 0 C C p F 2 CC p 2 a u 4 I s c c O 2 e e o 5 a o 5 i 2 i f 2 E C 52 ...
Страница 421: ...TEST SCOPE TRIGGERED ON U4105 PIN 9 FOR WAVEFORMS 121 AND 122 TEST SCOPE TRIGGERED ON U4227 PIN 10 i 4999 97 ...
Страница 423: ...W A V E F O R M SF O RD IA G R A M1 8 O c n ...
Страница 424: ...Figure 9 22 A11A1 Input Output board ...
Страница 427: ...WAVEFORMS FOR DIAGRAM 19 TEST SCOPE TRIGGERED ON U6103 PIN 1 FOR WAVEFORMS 126 AND 127 4999 98 ...
Страница 430: ...Figure 9 23 A11A2 Vector Generator board ...
Страница 434: ...49 9 9 tOO ...
Страница 436: ......
Страница 437: ...22 3 0 S ervice W A V E F O R M S F O R D I A G R A M 2 1 m f n h ...
Страница 442: ...WAVEFORMS FOR DIAGRAM 22 4999 78 ...
Страница 443: ...XY PLOTTER BOARD DIAGRAM 22 See Parts List for serial number ranges ...
Страница 444: ... u i o IO U J J i o D U I 1 t ir u j t O 0 X I c a a 3 4 2230 4999 71 REV FE8 1987 XY PLOTTER BOARD 22 ...
Страница 447: ...A21 RS 232 OPTION BOARD Flfi A 9 K 01 01 W M ...
Страница 450: ......
Страница 452: ...COMPONENT NUMBER EXAMPLE ...
Страница 455: ...r n n i i i i n O T IA ll D A A o n XY PLOTTER BOARD P in A23 OPTION MEMORY BOARD FIG 9 27 A22 GPIB OPTION BOARD ...
Страница 459: ...A16 SWEEP REFERENCE ADJUSTMENT LOCATION ...
Страница 467: ...2230 Service ...
Страница 468: ......
Страница 474: ......
Страница 475: ...2230 Service ...
Страница 476: ...2230 Service ...
Страница 477: ... D ...
Страница 483: ...2230 Service ...