System Installation and Setup
from System
to update the configuration in the Config Tool.
Select
File>Save Configuration
to save your programming changes.
Adding Tek-CARE
®
550 Transmitters with the Config Tool
In certain cases, adding transmitters manually through the Config Tool is preferable to
adding them automatically in the Event Monitor. These situations may include when
two independent Tek-CARE
®
550 systems are located in close proximity to each other
or if a small number of devices need to be added to an existing system. The Config Tool
method requires that certain information about the transmitters be entered manually.
1. With the Event Monitor software running, open the
Config Tool
software and
choose the appropriate network interface. On the right side of the Config Tool
splash screen, choose
Load Configuration from System
to ensure that the most
current configuration will be edited.
2. Select
Transmitters
in the page selection pane.
3. Click the
Add
button in the
Transmitters
pane. This unlocks the
Details
pane
for editing.
4. In the
Details
pane, select
TC550
from the
Transmitter Family
drop-down box
to add Tek-CARE
®
550 transmitters.
5. Choose a four digit
Device Number (Dev#)
to be assigned to the device to be
added and type it into the box.
6. Open the case of the device to be added. Find the eight digit long address sticker
located on the circuit board and copy it into the
Long Address
field in the
Details
pane. Add four zeroes to the beginning of the long address. The
7. If the device will be used immediately, ensure that the
In Use
box is checked.
If the device is to be placed in reserve, but not to be enabled until a later time,
leave this box unchecked. Before placing the device in reserve or storage, remove
the battery from the device.
8. Select the appropriate device type from the
Hardware
drop-down menu. If
adding an
SF559 Two-Button Pull Cord Station
, choose the entry from the
Used As:
drop down menu that matches the button insert placed in the device.
9. If the transmitter will be powered by a plug-in power supply, be sure and check
the
Line Powered
box.
10. If the device is being added to an existing system, choose the appropriate
location (if any) from the
Location
drop-down menu in the
Assignment
pane.
If the device is being added to a new system, select
Nowhere
as the location.
Locations will be added later.
Select
File>Save Configuration
to save your programming changes, then select
File>Commit Configuration to System
to update the Tek-Care
®
system.
Add Facility Maps and Locations
The Tek-CARE
®
system has the option to store maps of the care facility it is installed
in. These maps can be used to view transmitter locations and, when adding resident
information, associate a particular transmitter with a room, and thus an individual
resident entry.
Locations are where transmitters are physically installed throughout the facility.
Locations must be defined whether or not facility maps are used. Each stationary
IL948 Tek-CARE
®
500 & Tek-CARE
®
550 Installation Manual • 17