![TekTone Tek-CARE 550 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/tektone/tek-care-550/tek-care-550_installation-and-operation-manual_1077333013.webp)
System Installation and Setup
SF525ES and SF525/2ES NO/NC Universal Contact Transmitters:
The SF525ES
and SF525/2ES transmitters are used with any standard NO or NC switch, enabling
the Tek-CARE
®
500 system to monitor a variety of inputs. The SF525ES includes one
selectable NO/NC inputs and the SF525/2E includes one selectable NO/NC input plus
an NC-only input. The secondary NC-only input’s call type has not been preassigned.
The call type must be assigned using the Hardware page in the Config Tool software.
Alarms are automatically reset when returned to a normal state or when calls are reset
at the Tek-BRIDGE™ depending on system programming.
SF527ES Wireless Support Module:
The SF527ES Wireless Support Module may be
connected to an SF337C Waterproof Switch or SF339 Pushbutton Emergency Switch
to allow these switches to operate as wireless devices. This is especially useful in an
environment such as a shower or bathroom where calls must be easily placed and
water resistance is desired.
SF529ES Resident Check-In/Assistance Call Station:
The Wireless Resident Check-In
and Assistance Station is used when both a high-priority call and resident check-in is
desired. High priority calls must be reset at the point of origin.The SF529ES Resident
Check-In/Assistance Call Station includes a plastic pull cord kit.
SF530ES Room Station:
The Room Station transmitter is used where use of call cords
are desired. Alarms must be reset at the point of origin. The SF530ES Room Station
provides a standard 1/4” call cord receptacle and a reset pushbutton. The device also
includes cord-out detection, annunciated at the Tek-BRIDGE™.
SF531ES Emergency Switch:
The SF531 Emergency Switch is used where a high
priority call is desired, but water resistance is not required. The SF531ES Emergency
Switch includes a plastic pull-cord kit. Alarms placed from the transmitter must be
reset at the point of origin.
SF505ES Smoke Detector:
The SF505ES Smoke Detector transmits an alarm signal
when the smoke detector is activated. The signal will reset automatically when the
detector is clear of all smoke.
SF515ES Motion Detector:
The SF515ES Passive Infra-Red Motion Detector is sensitive
to moving heat sources. It can be used as a check-in device or as a security device on
the Tek-CARE
®
500 system.
IL948 Tek-CARE
®
500 & Tek-CARE
®
550 Installation Manual • 5
Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.