5-16
S-Curve Speed Command Acceleration/Deceleration:
Set
Sn205=3
to enable the use of S-Curve speed command ac/deceleration function.
Parameter
Name
Default
Unit
Setting range
Control mode
Sn208
S-Curve speed command
accel/decel time setting
1 msec 1~1000
S
Sn209
S-Curve speed command
acceleration time setting
200 msec
0~10000
S
Sn210
S-Curve speed command
deceleration time setting
200 msec
0~10000
S
In applications where normal acceleration/deceleration on ramp up or ramp down bring in vibration of the
mechanical system. S- curve acceleration/deceleration parameters could help to reduce vibration as
diagram below:
Speed Command (rpm)
Time (ms)
ts
ts
ta
ts
ts
td
ts=Sn208
ta=Sn209
td=Sn210
Caution! Setting Rule:
s
a
t
t
>
2
,
s
d
t
t
>
2