7-1-3 Modbus communication protocol for RS-485
The MODBUS protocol allows an easy communication within types of network architectures,before start to
communication with slave device, set the ID number (
Cn036
) for Servo drive respectively, server distinguish ID
number for controlling specific client station.
Standard Modbus networks combine two transmission modes: ASCII or RTU: ASCII(American Standard Code
for information interchange) Mode and RTU (Remote Terminal Unit) Mode, Use
Cn038 to
select ASCII or RTU
mode.
Coding method
ASCII Mode
8-bits Data consist of two ASCII code.
Ex: Data 26H 1-byte , the ’26’ convert to ASCII code is include character ’2‘
Æ
<32H> and ’6’
Æ
<36H>
ASCII Chart ( 0 ~ 9 and A ~ F ):
Character ‘0’ ‘1’ ‘2’ ‘3’ ‘4’ ‘5’ ‘6’ ‘7’
ASCII code(Hex)
30H
31H
32H
33H
34H
35H
36H
37H
Character ‘8’ ‘9’ ‘A’ ‘B’ ‘C’ ‘D’ ‘E’ ‘F’
ASCII code(Hex)
38H
39H
41H
42H
43H
44H
45H
46H
RTU Mode
Each 8bits is consist of 2 Hex number (4-bits per Hex number).
Ex.: Data 26H, the data length is 1-byte.
Содержание TSTA Series
Страница 1: ......
Страница 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Страница 15: ......
Страница 41: ...2 26 2 3 2 Position Control Mode Pe Mode Open Collector Pe mode External pulse positioning command ...
Страница 45: ......
Страница 59: ......
Страница 69: ......
Страница 175: ......
Страница 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Страница 207: ...9 5 Dimension for TSTA 30 ...
Страница 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Страница 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Страница 214: ......
Страница 215: ......
Страница 218: ......