![Teco Electro Drives TSTA Series Скачать руководство пользователя страница 133](http://html.mh-extra.com/html/teco-electro-drives/tsta-series/tsta-series_installation-and-operation-manual_1072528133.webp)
5-64
Digital Outputs.
There are 4 programmable Digital Outputs according to the table below:
Parameter
Name
Setting
Description
Control
Mode
Code
Contactor functions
01
RDY
Servo Ready
02
ALM
Alarm
03
ZS
Zero Speed
04
BI
Brake Signal
05
INS
In Speed
06
INP
In Position
07
HOME
HOME
★
Hn514.0
★
Hn514.1
DO-1 Logic
state
08
INT
In Torque
ALL
0
Close, when the output is activated.
★
Hn514.2
DO-1
1
Open, when the output is activated..
ALL
Parameter
Name
Description
Control
Mode
★
Hn515
DO-2
Programmable
★
Hn516
DO-3
Programmable
★
Hn517
DO-4
Programmable
Refer to
Hn514
for programmable options.
ALL
New setting will become effective after re-cycling the power.
Warning!
When programmable DO-1 ~ DO-4 are set for the same type of function alarm will be displayed.
AL-07 (
Multi-function contact setting error
).
Содержание TSTA Series
Страница 1: ......
Страница 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Страница 15: ......
Страница 41: ...2 26 2 3 2 Position Control Mode Pe Mode Open Collector Pe mode External pulse positioning command ...
Страница 45: ......
Страница 59: ......
Страница 69: ......
Страница 175: ......
Страница 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Страница 207: ...9 5 Dimension for TSTA 30 ...
Страница 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Страница 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Страница 214: ......
Страница 215: ......
Страница 218: ......