Digital Output Function Explanation
(The terminal layout here from this explanation are all the low electric potential, please refer to 5-6-1 to check
parameter settings)
Signal Name
Function
Symbol
Mode I/O
Function
Chapter
Servo Ready
RDY
ALL
Main power and control power input are normal. Under the
situation of no alarm, terminal layouts
RDY
and
IG24
close
loop.
―
Alarm
ALM
ALL
If normally operates, the terminal layouts
ALM
and
IG24
open
loop. When alarm occurs, protection-function operates, the
terminal and
IG24
close loop.
―
Zero Speed
ZS
S
When the motor speed is less than the speed from
Sn215,
the
terminal layout
ZS
and
IG24
close loop.
5-3-12
BK Signal
BI
ALL
When
Cn008
is set “1” or “3” and the servo on, the terminal
layout
BI
and
IG24
close loop; when servo off , terminal layout
and
IG24
open loop. (When this terminal layout is generally
applied, it is the Brake relay, which is connected to control
motor).
5-6-4
5-6-5
In Speed
INS
S
When the motor speed has achieved the setting speed from
Cn007,
INS
and
IG24
close loop.
5-3-12
In Position
INP
Pi/Pe
When the amount of position error counter is less than the
amount range which is set in
Pn307, INP and IG24
close loop.
5-4-9
Home
HOME
Pi/Pe When HOME is accomplished,
HOME
and
IG24
close.
5-4-8
Limiting Torque/
Alarm No. 0
LM/A0
ALL
When motor output torque is limited by internal torque limit
amount (
Cn010&Cn011)
or external torque limit command
(
PIC&NIC)
.
LM/A0
and
IG24
close loop.
When alarm occurs, this terminal layout is alarm code output
A0
.
8-1
P in Action /
Alarm No.1
PC/A1
Pe/Pi/S
When speed loop is ratio(P)-control,
PC/A1
and
IG24
close
loop.
When alarm occurs, this terminal layout is alarm code output
A1
.
8-1
Server in Limiting/
Alarm No.2
ST/A2
ALL
When CCW or CW operation-limit occurs,
ST/A2
and
IG24
close loop.
When alarm occurs, this terminal layout is alarm code output
A2
8-1
Base Block/
Alarm No.3
BB/A3
ALL
When servo motor has not be operated,
BB/A3
and
IG24
close
loop.
When alarm occurs, this terminal layout is alarm code output
A3
8-1
Содержание TSTA Series
Страница 1: ......
Страница 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Страница 15: ......
Страница 41: ...2 26 2 3 2 Position Control Mode Pe Mode Open Collector Pe mode External pulse positioning command ...
Страница 45: ......
Страница 59: ......
Страница 69: ......
Страница 175: ......
Страница 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Страница 207: ...9 5 Dimension for TSTA 30 ...
Страница 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Страница 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Страница 214: ......
Страница 215: ......
Страница 218: ......