![Teco Electro Drives TSTA Series Скачать руководство пользователя страница 67](http://html.mh-extra.com/html/teco-electro-drives/tsta-series/tsta-series_installation-and-operation-manual_1072528067.webp)
4-8
C.
Position control mode trial run (Cn001=2).
1. Wiring:
Check and ensure that all power connections to the drive and motor and control signal connections are correct as
diagram below.
2. Setting electronic gear ratio.
Set electronic gear ratio parameters Pn302~Pn306 as required for the positioning application.
(refer to section 5-4-3).
Note: Electronic gear ratio parameter can be used to scale the command output pulse.
This would be useful in transmission applications where move distance per move command pulse
has to be scaled due to mechanical requirements.
3. Apply
Servo
on.
Apply power to the drive and activate (
SON
) signal by switching SON terminal to IG24 (input digital Ground).
4. Confirm motor speed, direction and number of revolutions.
Apply a low-speed pulse command from the host controller to the servo drive so that the servo motor
operates at low-speed.
Compare the number of pulses per revolution from parameters
Un-15
( motor feed back pulse ppr)
and
Un-17
(Input command ppr) these should be the same.
Compare the number of revolutions using parameters Un-14 ( motor feed back rotation number) and
Un-16 (pulse command rotation number) these should be the same.
If there are differences then adjust electronic gear ratio parameters
Pn302~Pn306
as required and test
again until the result is satisfactory.
If the direction of motor rotation is incorrect then check and if necessary set parameter Pn 301.0
(position pulse command types).
Also check and if necessary set parameter
Pn314
(Position command direction selection).
Once the test result is correct then remove SON signal. (Power to the motor is switched off).
Содержание TSTA Series
Страница 1: ......
Страница 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Страница 15: ......
Страница 41: ...2 26 2 3 2 Position Control Mode Pe Mode Open Collector Pe mode External pulse positioning command ...
Страница 45: ......
Страница 59: ......
Страница 69: ......
Страница 175: ......
Страница 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Страница 207: ...9 5 Dimension for TSTA 30 ...
Страница 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Страница 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Страница 214: ......
Страница 215: ......
Страница 218: ......