4-3
Steps for setting parameter Cn002.1 ( CCWL &CWL Rotation limit selection).
Setp Keys
LED
Display
Description
1 Power
on
On” power on “
Drive Status
is displayed.
2
Press
MODE-Key
4 times to display Cn001.
3
Press
INCREMENT-Key
once to display Cn002.
4
Press
ENTER-Key
for 2 secs to display the preset value of
Cn002. Note: Cn 002 includes 4 digits corresponding to
Cn002.0,Cn002.1,Cn002.2 & Cn002.3.
5
Press ENTER-Key once to move to the 2
nd
digit for (Cn 002.1).
6
Press
INCREMENT- Key
once to adjust the 2
nd
digit to 1.
Disable the function of external limits CCWL and CWL.
7
To save the setting value by
Press the
ENTER- Key
for 2 seconds until
“SET”
is displayed
briefly and then display is returned to parameter Cn-002.
After accomplish these steps, reset the power. If there are any other alarms then
refer to section
8-2 (Clearing Alarms)
. Once there is no alarms then operate the drive again.
If any of the alarms can not be cleared, please contact your local supplier for assistance.
4. Mechanical Brake Release.
When a brake type servo motor is used then must release the brake before starting trial run
by applying 24vdc voltage to brake terminals.
5. Keypad Trial run (JOG function).
Jog function can be used to check if motor speed and rotation direction is correct.
Parameters Sn 201(internal speed command 1) and Cn004 (motor rotation direction selection)
Can be used to set the required speed and direction.
Warning!
Set the required JOG speed before the trial run otherwise the motor will run at the default speed set in
parameter Sn201(internal speed command 1).
Warning!
Regardless of external SON (servo on) is active of not, Servo motor will get excitation as soon as JOG is
activated.
Содержание TSTA Series
Страница 1: ......
Страница 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Страница 15: ......
Страница 41: ...2 26 2 3 2 Position Control Mode Pe Mode Open Collector Pe mode External pulse positioning command ...
Страница 45: ......
Страница 59: ......
Страница 69: ......
Страница 175: ......
Страница 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Страница 207: ...9 5 Dimension for TSTA 30 ...
Страница 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Страница 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Страница 214: ......
Страница 215: ......
Страница 218: ......