![Tecnoalarm TP8-64 Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/tecnoalarm/tp8-64/tp8-64_user-manual_1071819070.webp)
Control by keypoint
User Manual -
TP8-64
5-12
5.4.3.3
DEACTIVATION OF BY-PASS WITH CODE
Enter a code enabled for by-pass (master or standard user code enabled for the programs armed) followed by the
number of the program to be reactivated in its integrity, e.g.:
+
66778
+
1
The LED of the program previously partset becomes lit.
5.4.4
SPECIAL OPERATING CONDITIONS
5.4.4.1
FALSE CODE ALARM
The alarm is released when 32 keys are pressed without entering a valid code.
In case of false code alarm, the red LED 6 general alarm starts blinking.
The keypad which the false code has been entered on is disabled for 2 minutes. Simultaneously, the buzzers of all the
consoles connected are activated and the OCG and key LED of all the key readers and consoles are blinking. To stop
the alarm introduce a valid key or enter a valid code (master or standard user code) on another control unit connected.
5.4.4.2
SIMULTANEOUS ARMING BY SEVERAL CONTROL UNITS
During the arming process by console, all the electronic keypads are disabled.
When trying to arm the control panel in this situation by electronic keypad, the 3 LED on the keypad blink for
approximately 3 seconds.
5.4.4.3
AUTOMATIC COMMUNICATOR BLOCK
If enabled by the holder of the master code, on disarming of a program the active telephone channels are blocked
automatically.
5.4.4.4
GENERAL ALARM
If a general alarm is active (the corresponding LED is blinking), arming of the control panel is not permitted with code
unless the code is enabled for the by-pass of the general alarms.
WARNING
Outside the access periods associated the codes are not accepted by the control panel and any
attempt at acceding to the system will have no effect.
When trying to do so, the system ignores the command.
The green LED 5 remains lit and the red program LED remain off.
After 5 seconds, the electronic keypad returns to stand-by.
WARNING
It is possible to use only one control unit at a time.
Содержание TP8-64
Страница 4: ...IV UserManual TP8 64...
Страница 8: ...Index User Manual TP8 64 4...
Страница 10: ...Notes User Manual TP8 64 II...
Страница 26: ...Signaling UserManual TP8 64 2 12...
Страница 42: ...Programming UserManual TP8 64 3 16...
Страница 45: ...TP8 64 UserManual Control by console 4 3 OPERATIONSWITHOUTCODE...
Страница 47: ...TP8 64 UserManual Control by console 4 5 LCD200CONSOLE LCD300 SCONSOLE...
Страница 58: ...Control by console UserManual TP8 64 4 16...