5-3
Once the exit time has expired, the yellow program LED become lit and remain lit until
disarming of these programs.
If the programs selected do not contain delayed zones, on expiry (or abort) of the zone
exclusion time, the programs in question are armed and the corresponding yellow LED
become lit immediately.
5.1.1.1 EXCLUSION OF OPEN ZONES
After selecting the programs to be armed, during the 10-seconds zone exclusion time, if
there are open zones, the yellow OCG LED becomes blinking.
A zone may result open for instance in case of fault of the detector connected.
To arm the programs selected excluding the open zones press:
+
l
The zones remain excluded until disarming of the program. They are activated
automatically again the next time the program is armed.
5.1.2 DISARMING
Introduce the electronic key into the key reader.
The green key LED is lit.
For the 10 seconds to come it is possible to select the programs to be disarmed.
On every keystroke the counter is reset.
Select the programs to be disarmed, e.g.:
+
1
The yellow LED corresponding to the programs selected are switched off.
It is possible to confirm the selection and abort the 10-seconds wait by removing the
electronic key from the key reader.
The green key LED is switched off.
5.1.3 BY-PASS
When the control panel is armed, it is possible to deactivate temporaneously part of the
system. Upon activation of the by-pass, the zones enabled for by-pass and included in
the program/s armed and partset are deactivated. The other zones are not affected.
The exclusion of zones persists until deactivation of by-pass or disarming of the
programs they are included in.
Introduce an electronic key enabled for by-pass into the key reader.
The yellow LED corresponding to the programs partset become blinking.
Remove the electronic key from the key reader.
5.1.3.1 ACTIVATION OF BY-PASS DURING THE ACCESS PERIODS
It is possible to define up to 8 access periods of the electronic keys. As a consequence,
the electronic keys are enabled for by-pass during the access periods associated by the
installer or the holder of the master code only.
WARNING
If the open zones are not excluded, on expiry of the zone exclusion time (and perhaps the exit time) the
programs are armed and the open zones are activated. Consequently the alarm is released.
WARNING
The electronic key introduced will effect disarming exclusively of those programs it is enabled for. Other
armed programs are not affected.
WARNING
The zones excluded are those associated to the by-pass function and included in the programs
associated to the key. All the programs associated to the electronic key introduced are partset
simultaneously. If one of the programs associated is already partset, the introduction of the key causes
the reactivation of this program in its integrity.
Содержание TP8-64
Страница 4: ...IV UserManual TP8 64...
Страница 8: ...Index User Manual TP8 64 4...
Страница 10: ...Notes User Manual TP8 64 II...
Страница 26: ...Signaling UserManual TP8 64 2 12...
Страница 42: ...Programming UserManual TP8 64 3 16...
Страница 45: ...TP8 64 UserManual Control by console 4 3 OPERATIONSWITHOUTCODE...
Страница 47: ...TP8 64 UserManual Control by console 4 5 LCD200CONSOLE LCD300 SCONSOLE...
Страница 58: ...Control by console UserManual TP8 64 4 16...