Control by console
User Manual -
TP8-64
4-10
4.2.3
DISARMING UNDER DURESS (IF ENABLED)
In case of robbery, it is possible to simulate disarming of the system and release
simultaneously a hold-up alarm.
For this enter the master code or a standard user code (enabled for the programs
armed) reducing the last digit by one unit, e.g. master code (default code 12345):
+
12344
The control panel is apparently disarmed, i.e. all the program LED are switched off, and
if programmed appropriately by the installer, the logic outputs OUT1 or OUT2 of the CPU
board and all the modules connected and a telephone call for hold-up alarm are
activated.
4.2.4
QUICK DISARMING (IF ENABLED)
It is possible to speed up the disarming process by pressing the key * (star) followed by
the program number, e.g.:
+
*1
+
*2
Repeat the command for all the programs to be disarmed.
4.2.5
DISARMING THROUGH KEY ZONE
The control panel can be disarmed through a contact connected to a zone programmed
by the installer as key zone.
Every time the contact is opened, all the programs that contain the key zone are
disarmed.
4.2.6
AUTOMATIC DISARMING
The control panel can be disarmed automatically using the 16 timers. Therefore, it is
possible to schedule disarming with a determined frequency and at a determined time
acting on determined programs.
At the time programmed the timer disarms the programs associated.
4.2.7
DISARMING DURING ACCESS PERIODS
It is possible to define up to 8 access periods of the codes. As a consequence, the
codes are enabled for arming and disarming during the access periods associated by
the installer or the holder of the master code only.
4.3
BY-PASS
When the control panel is armed, it is possible to deactivate temporaneously part of the
system. Upon activation of the by-pass, the zones enabled for by-pass and included in
the program/s armed and partset are deactivated. The other zones are not affected.
The exclusion of zones persists until deactivation of by-pass or disarming of the
programs they are included in.
4.3.1
BY-PASS ACTIVATION WITH CODE
Enter a code enabled for by-pass (master or standard user code enabled for the
programs armed) followed by the number of the program to be partset, e.g.:
+
66778
+
12
On the display is viewed
Act. by-pass
followed by the program partset.
For the time the by-pass is active the corresponding program LED is blinking.
WARNING
Disarming by hold-up code (disarming under duress) causes no signaling by the console. The event is
stored in the event buffer.
If the user code ends on 0, e.g. 43670, the hold-up code ends on 9, in this case 43679.
WARNING
Outside the access periods associated the codes are not accepted by the control and any attempt at
acceding to the system will have no effect.
When trying to do so, on the display is viewed
ACCESS ! DENIED !
.
Act. by-pass
Program 1
Содержание TP8-64
Страница 4: ...IV UserManual TP8 64...
Страница 8: ...Index User Manual TP8 64 4...
Страница 10: ...Notes User Manual TP8 64 II...
Страница 26: ...Signaling UserManual TP8 64 2 12...
Страница 42: ...Programming UserManual TP8 64 3 16...
Страница 45: ...TP8 64 UserManual Control by console 4 3 OPERATIONSWITHOUTCODE...
Страница 47: ...TP8 64 UserManual Control by console 4 5 LCD200CONSOLE LCD300 SCONSOLE...
Страница 58: ...Control by console UserManual TP8 64 4 16...