2.4
LED SIGNALING OF THE ATPK KEY READER
The ATPK key reader provides coloured LED for signlaing of the alarms and system status.
2.4.1
PROGRAM STATUS LED - RED, YELLOW, GREEN
The program status LED signal the status of the first 3 programs (1...3) as follows:
z
LED blinking quickly
= the pre-arming phase is active.
The pre-arming phase permits arming/disarming of other programs. Then, the volontary
exclusion of zones from the detection of alarms is possible.
z
LED blinking slowly
= the program is partset.
The zones included in the by-pass program are temporarily disabled from the detection of
alarms.
z
LED on
= the program is armed
z
LED off
= the program is in stand-by
Arming and disarming as well as the activation and deactivation of by-pass are logged in the event buffer of the control
panel.
2.4.2
PROGRAM AND GENERAL ALARM LED - YELLOW
The general alarm LED signals the alarms as follows:
z
LED blinking
= a program or general alarm is active
z
LED on
= a program or general alarm has been stopped and stored in the event buffer of the
control panel (alarm memory)
z
LED off
= no alarm has occurred
The alarms are logged in the event buffer of the control panel.
The alarm LED signals:
z
Program alarm
One of the first 3 programs is in alarm.
z
Antimasking alarm
The radio receiver has been jammed.
z
Supervision alarm
One of the radio devices has not transmitted any test signal/alarm for a period superior to the supervision interval
programmed.
z
False key
An unknown key has been inserted in one of the keypoint connected.
z
False code
32 or more keys have been pressed on one of the consoles and keypads connected without entering a valid code.
z
GSM fault
The mobile phone does not answer to the interrogations by the GSM interface TECNOCELL for a period of
approximately 10s.
z
Cut telephone line
The telephone line voltage is missing for a period of approximately 1 minute.
z
Low battery
The battery voltage has fallen to a value below the minimum guaranteeing correct functioning of the control panel
(<11V) or voltage of the battery of one of the radio devices connected is insufficient (<2.7V).
z
Power failure (230V AC)
LED off
LED blinking quickly
LED blinking slowly
LED on
Program in stand-by
Program in pre-arming phase
Program partset
Program armed
LED éteinte
LED clignotante
LED allumée
No alarm
Alarm active
Alarm stored (alarm memory)
LED STATUS PROGRAM (1…3)
1
LED GENERAL ALARM
2
Содержание TP8-64
Страница 4: ...IV UserManual TP8 64...
Страница 8: ...Index User Manual TP8 64 4...
Страница 10: ...Notes User Manual TP8 64 II...
Страница 26: ...Signaling UserManual TP8 64 2 12...
Страница 42: ...Programming UserManual TP8 64 3 16...
Страница 45: ...TP8 64 UserManual Control by console 4 3 OPERATIONSWITHOUTCODE...
Страница 47: ...TP8 64 UserManual Control by console 4 5 LCD200CONSOLE LCD300 SCONSOLE...
Страница 58: ...Control by console UserManual TP8 64 4 16...