Signaling
User Manual -
TP8-64
2-4
BATTERY LED
The battery LED signals low battery alarms as follows:
z
LED blinking
= battery voltage is inferior to 11V or voltage of the battery of the
radio devices is inferior to 2.7V.
z
LED on
= battery voltage has returned to accepted values and the alarm
has been stored in the event buffer of the control panel (alarm
memory).
To find out the battery of which radio device has caused the alarm, view the events
logged in the buffer.
Both events, beginning and end of low battery alarm, are logged in the event buffer of the
control panel.
Signaling on display
In addition to LED signaling, low battery alarms are signalled on the display of the
console with indication of the radio module interested, if necessary.
MAINS LED
The power failure alarm is a direct alarm and always enabled (even if the control panel is
in stand-by).
It is released as soon as mains power (230V AC) is missing, unless a delay of power
failure alarm has been programmed. The delay can be programmed in 10-minutes steps
from a minimum of 10 minutes to a maximum of 9 hours and 50 minutes. This is avoid
false alarms in case of sudden voltage drops or short-term mains disconnection for
maintenance on the electric installation.
The mains LED signals power failure alarms as follows:
z
LED blinking
= power failure alarm active.
z
LED on
= mains power has returned to accepted values and the alarm has
been stored in the event buffer of the control panel (alarm
memory).
Both events, beginning and end of power failure alarm, are logged in the event buffer of
the control panel.
GENERAL ALARM LED
The general alarms are direct alarms that are always enabled.
Among the general alarms count:
z
Antimasking alarm
The radio receiver has been jammed.
z
Supervision alarm
One of the radio devices has not transmitted any test signal/alarm for a period
superior to the supervision interval programmed.
z
False key
An unknown key has been inserted in one of the key reader connected.
z
False code
32 or more keys have been pressed on one of the consoles and keypads connected
without entering a valid code.
z
GSM fault
Communication with GSM telephone communicator lost, SIM card missing.
LOW BATTERY
Ctrl panel
WARNING
In case of tamper alarm, arming is denied and is displayed
! Arming denied !
, unless the code used
for arming has be enabled for the by-pass of general alarms (see programming). To re-establish normal
functioning conditions, eliminate the reason for alarm.
Tamper alarm memory signaling cannot be cancelled by the user, address your installer.
WARNING
If while mains power is missing, the voltage of the battery drops below the minimum
value guaranteeing correct functioning of the control panel (inferior to 9V), the battery
is automatically disconnected in order to protect it from final and irreversible
discharge.
In this case, the system loses all date/time settings as, merely system status and
alarm memory signaling in maintained.
On return of battery voltage or battery replacement, the displays of the consoles
show the date and time with an invalid month field. All date/time settings must be
programmed again, otherwise the scheduled functions such as automatic arming and
test call will remain disabled.
Fri
01 --- 00
Work.
00:01
Содержание TP8-64
Страница 4: ...IV UserManual TP8 64...
Страница 8: ...Index User Manual TP8 64 4...
Страница 10: ...Notes User Manual TP8 64 II...
Страница 26: ...Signaling UserManual TP8 64 2 12...
Страница 42: ...Programming UserManual TP8 64 3 16...
Страница 45: ...TP8 64 UserManual Control by console 4 3 OPERATIONSWITHOUTCODE...
Страница 47: ...TP8 64 UserManual Control by console 4 5 LCD200CONSOLE LCD300 SCONSOLE...
Страница 58: ...Control by console UserManual TP8 64 4 16...