3.12 TEST
Select the menu Test and confirm by clicking on the
#
key.
+
#
to confirm
Submenus
z
Zones
Functioning test of the zones
z
Indoor siren
Functioning test of the indoor siren
z
Outdoor siren
Functioning test of the outdoor siren
z
Version
Viewing of the firmware versione of the control panel
z
Vocal synthesis
Viewing of the vocabulary version of the control panel
z
LED console
Viewing of the LED status of the console
z
GSM
Viewing of the tel. communicator with GSM module status
The tests are automatically executed in this order. They can be interrupted or skipped
by pressing
EXIT
.
3.12.1
ZONE TEST
Permits the test of both the wired and radio detectors of the system.
On the display is viewed - - - for the entire zone test.
Pass by the detectors soliciting the activation of the zone contacts.
For every zone that is found open, the buzzer of the console is activated for approx. 2s
and after the test the open zones are viewed on the display.
The test has no determined duration.
Commands available
+
yw
to view the open zones one by one
+
EXIT
to quit the submenu
3.12.2
INDOOR SIREN TEST
Permits the test of the indoor sirens and the battery of the system.The test takes 60s
and can be interrupted by pressing
EXIT
.
The sirens are activated and powered by battery.
After the test, if battery voltage is found low, the battery LED is blinking.
Commands available
+
EXIT
to quit the submenu
3.12.3.
OUTDOOR SIREN TEST
Permits the test of the outdoor sirens and the battery of the system.
The test takes 60s and can be interrupted by pressing
EXIT
.
The sirens are activated and powered by battery.
After the test, if battery voltage is found low, the battery LED is blinking.
Commands available
+
EXIT
to quit the submenu
3.12.4
VIEWING OF THE FIRMWARE VERSION
On initiation, on the display is viewed the release and the language of the firmware of the
control panel.
Commands available
+
EXIT
to quit the submenu
3.12.5
VIEWING OF THE VOCABULARY VERSION
On initiation, on the display is viewed the release and the language of the vocabulary of
the control panel.
Commands available
+
EXIT
to quit the submenu
3.12.6
VIEWING OF THE LED STATUS
On initiation, all the LED on the console are lit and the buzzer is activated.
Commands available
+
EXIT
to quit the submenu
Menu
18
Test
Test
2
Zones
Zones
- - -
Zones
Zone 25
Test
3
Indoor siren
Test
4
Outdoor siren
Test
5
Version
(c) Tecnoalarm
TP64 v.2.3 ENG
Test
6
Vocal synthesis
(c) Tecnoalarm
Vocab. v.3.0 ENG
Test
7
LED console
LED console
WARNING
During the test, the wireless indoor/outdoor sirens work according to programming, i.e. not active,
sounding, flashing, sflashing. The sounding or flashing time, however, is irrelevant.
Содержание TP8-64
Страница 4: ...IV UserManual TP8 64...
Страница 8: ...Index User Manual TP8 64 4...
Страница 10: ...Notes User Manual TP8 64 II...
Страница 26: ...Signaling UserManual TP8 64 2 12...
Страница 42: ...Programming UserManual TP8 64 3 16...
Страница 45: ...TP8 64 UserManual Control by console 4 3 OPERATIONSWITHOUTCODE...
Страница 47: ...TP8 64 UserManual Control by console 4 5 LCD200CONSOLE LCD300 SCONSOLE...
Страница 58: ...Control by console UserManual TP8 64 4 16...