Control by keypoint
User Manual -
TP8-64
5-2
CHECK ZONE AND SYSTEM STATUS
Prior to arming of the control panel, when the control panel is in stand-by, always check
the status of the zones and the system with the help of the LED:
z
Red program alarm LED
blinking
= program alarm active
on
= alarm memory
z
Red general alarm LED
blinking
= trouble or general alarm active (e.g. low battery,
power failure, tamper)
on
= alarm memory
z
Yellow OCG LED
blinking
= zones not OK during the arming phase
CHECK PROGRAM LED STATUS
The yellow LED indicate the status of the 6 programs associated:
z
LED on
= program armed
z
LED off
= program in stand-by
z
LED blinking quickly
(2 flashes per second)
= exit time, arming phase or warning of end of
by-pass active
z
LED blinking slowly
(1 flash per second)
= program partset or not OK during the arming
phase
Introduce the electronic key into the key reader.
The green key LED is lit.
For the 10 seconds to come it is possible to select the programs (1 to 6) to be armed.
On every keystroke the counter is reset.
Select the programs to be armed, e.g.:
+
12
After selecting the programs, for 10 seconds, the yellow LED corresponding to the
programs selected are blinking.
ZONE EXCLUSION TIME
For 10 seconds after selecting the programs, it is possible to exclude manually some of
the zones from the detection of alarms with a procedure explained lateron.
If you do not wish to exclude any zone, it is possible to confirm the selection without
awaiting the expiry of the zone exclusion time by removing the electronic key.
The green key LED is switched off.
EXIT TIME
The zones defined as delayed, upon arming observe the exit time programmed by the
installer.
If the programs selected contain delayed zones, on expiry of the zone exclusion time
follows the exit time and the programs in question are only armed on expiry of the exit
time.
WARNING
The electronic key introduced will effect arming exclusively of those programs it is enabled for.
WARNING
To abort arming of the programs selected press the key
F3
. The process is aborted and the control
panel returns to stand-by.
WARNING
On arming of a program in presence of open zones, the alarm devices programmed are activated
(sirens/logic outputs/telephone channels) unless the open zones are excluded with a procedure
explained lateron.
Содержание TP8-64
Страница 4: ...IV UserManual TP8 64...
Страница 8: ...Index User Manual TP8 64 4...
Страница 10: ...Notes User Manual TP8 64 II...
Страница 26: ...Signaling UserManual TP8 64 2 12...
Страница 42: ...Programming UserManual TP8 64 3 16...
Страница 45: ...TP8 64 UserManual Control by console 4 3 OPERATIONSWITHOUTCODE...
Страница 47: ...TP8 64 UserManual Control by console 4 5 LCD200CONSOLE LCD300 SCONSOLE...
Страница 58: ...Control by console UserManual TP8 64 4 16...