![Technosoft iPOS4808 MYCAN-STO Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/technosoft/ipos4808-mycan-sto/ipos4808-mycan-sto_technical-reference_1070599039.webp)
Technosoft 2016
39
iPOS4808 MY-CAN-STO/-CAT-STO Technical Reference
3.9.3
Mechanical Mounting
Min.
Typ.
Max.
Units
Airflow
natural convection
, closed box
Spacing required for horizontal mounting.
Between adjacent drives
4
mm
Between drives and nearby walls
5
mm
Space needed for drive removal
10
mm
Between drives and roof-top
20
mm
Insertion force
Using recommended mating connectors
TBD
TBD
N
Extraction force
TBD
TBD
N
3.9.4
Environmental Characteristics
Min.
Typ.
Max.
Units
Size ( Length x Width x Height )
Global size
iPOS4808 MY-CAN-STO
60 x 43.6 x 22
mm
~2.36 x 1.72 x 0.87
inch
iPOS4808 MY-CAT-STO
64 x 43.6 x 22
mm
~2.52 x 1.72 x 0.87
inch
Weight
iPOS4808 MY-CAN-STO
43
g
iPOS4808 MY-CAT-STO
45
Cleaning agents
Dry cleaning is recommended
Only Water- or Alcohol- based
Protection degree
According to IEC60529, UL508
IP20
-
3.9.5
Logic Supply Input (+V
LOG
)
Min.
Typ.
Max.
Units
Supply voltage
Nominal values
9
36
V
DC
Absolute maximum values, drive operating but outside
guaranteed parameters
8
40
V
DC
Absolute maximum values, continuous
-0.6
42
V
DC
Absolute maximum values, surge
(duration
≤
10ms)
†
-1
+45
V
+V
LOG
= 12V
130
mA
+V
LOG
= 24V
90
280
+V
LOG
= 40V
85
3.9.6
Motor Supply Input (+V
MOT
)
Min.
Typ.
Max.
Units
Supply voltage
Nominal values
11
50
V
DC
Absolute maximum values, drive operating but outside
guaranteed parameters
9
52
V
DC
Absolute maximum values, continuous
-0.6
54
V
DC
Absolute maximum values, surge
(duration
≤
10ms)
†
-1
57
V
Supply current
Idle
1
5
mA
Operating
iPOS4808
-20
±8
+20
A
Absolute maximum value, short-circuit condition
(duration
≤
10ms)
†
iPOS4808
26
A
1
In case of forced cooling (conduction or ventilation) the spacing requirements may drop down to mechanical tolerances as long as
the ambient temperature is kept below the maximum operating limit