1.
All pins are sampled at power-up, and the drive is configured accordingly
If CANopen mode is selected and the AxisID is set to 255, the drive remains “non-configured” waiting for a CANopen
master to configure it, using CiA-305 protocol. A “non-configured” drive answers only to CiA-305 commands. All other
CANopen commands are ignored and transmission of all other messages (including boot-up) is disabled.
The Ready
(green) LED will flash at 1 second time intervals while in this mode
3.8 Axis ID Selection for CAT drives(J1 pin settings)
The iPOS4808 MY-CAT-STO drives support all EtherCAT standard addressing modes. In case of device
addressing mode based on node address, the iPOS4808 drive sets the
configured station alias
address with its
AxisID value. The drive AxisID value is set after power on by:
-
Software, setting via EasySetUp a specific AxisID value in the range 1-255.
-
Hardware, by setting h/w in Easy setup under Axis ID value and selecting a value between 1-127 from the pins
3-9
The Hardware Axis ID can be set by connecting J1 pins to GND.
ON = connect pin to GND (pin = 1)
OFF = leave pin unconnected (pin =0 )
An 8 pole DIN switch can be connected to these pins on a user motherboard.
Figure 3.35.
J1 – Axis ID pins
•
Pins 3 … 9
: ID-Bitx.
The drive axis/address number is set when H/W is selected in Drive Setup under AxisID field or when the
Setup is invalid.
The axis ID is an 8 bit unsigned number. Its first 7 bits are controlled by the ID-bit0 to ID-bit6. Bit7 of this
variable is always 0. In total, 127 axis ID HW values can result from the DIP switch combinations.
When pins 3..9 remain unconnected, the drive Axis ID will be 255 and
configured station alias
will be 0.
All pins are sampled at power-up, and the drive is configured accordingly
3.9 Electrical Specifications
All parameters measured under the following conditions (unless otherwise specified):
T
amb
= 0…40
°
C, V
LOG
= 24 V
DC
; V
MOT
= 48V
DC
; Supplies start-up / shutdown sequence: -
any-
Load current (sinusoidal amplitude / continuous BLDC,DC,stepper) = 8A iPOS4808
3.9.1
Operating Conditions
Min.
Typ.
Max.
Units
Ambient temperature
0
+40
ºC
Ambient humidity
Non-condensing
0
90
%Rh
Altitude / pressure
Altitude (referenced to sea level)
-0.1
0 ÷ 2.5
2
Km
Ambient Pressure
0
2
0.75 ÷ 1
10.0
atm
3.9.2
Storage Conditions
Min.
Typ.
Max.
Units
Ambient temperature
-40
100
ºC
Ambient humidity
Non-condensing
0
100
%Rh
Ambient Pressure
0
10.0
atm
ESD capability (Human body model)
Not powered; applies to any accessible part
±
0.5
kV
Original packaging
±
15
kV
1
Operating temperature at higher temperatures is possible with reduced current and power ratings
2
iPOS4808 can be operated in vacuum (no altitude restriction), but at altitudes over 2,500m, current and power rating are reduced