![Technische Alternative UVR 63 Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/technische-alternative/uvr-63/uvr-63_operation-and-installation-instructions_1069692076.webp)
76
Assignment of free outputs A2/A3 <= OFF
Outputs which do not have a fixed assignment in the diagram (diagram 0 to 159) can be
linked to other outputs.
A3 deactivated
A3 activated (as
time switch output)
A3 switches with A1
A3 switches with A2
A3 switches when
A1 and A2 are ON
A3 switches when
A1 or A2 are ON
A3
OFF
Output A3 has no function
A3
ON
Output A3 is released and available as e.g. time switch output
A3
A1
Output
A3
switches
together with output A1
A3
A2
Output
A3
switches
together with output A2
A3
1U2
Output A3 switches if output A1 and output A2 have activated.
A3 = A1 & A2
A3
1O2
Output A3 switches if output A1 or output A2 have activated.
A3 = A1 or A2
WARNING:
The switch function does not relate directly to the allocated output, rather only to
its function in the
Basic program
diagram, in which respect a possible priority
allocation is
not
considered. If this is necessary, program diagram 624 can be
used.If the output is to be affected by special functions (e.g. time window,
collector excess temperature limitation etc.) so that this is to be especially
allowed for when assigning outputs.