AIMA3000.RRAS/G/R Product User Manual
Technetix Group Limited
•
technetix.com
Jan/2018 - V2
39
7.2 Setting up the RF Input level
When the main RRAS / RRAG web interface is opened, on the left toolbar each port can be selected and confi gured
individually. The ports are listed as port 1 – 4. In the example below,
“Port 1”
is selected.
In the setup page for
”Port 1”
the operator can view the module’s status for the RRAS:
Field
Description
Factory Default Setting (bold)
and range if applicable
Input Status Alarm
Monitors Optical Input Level
Enable Major
Enable Minor
Disable
AGC Status Alarm
Monitors the mode for gain control
Enable Major
Enable Minor
Disable
Parameter
Units
HIHI
HI
Normal
LO
LOLO
Dead
Band
Input Power
dBm
3
2,5
-
-18,5
-19,5
0,2
Содержание AIMA3000