Spectrum interface includes three parts: Spectrum, Select Channel and Spectrum Configuration.
For Select Channel, the items and buttons are shown as below:
Slot means choose the slot number in the chassis, Port means choose the port number that you need to see the spectrum
of the module.
For Spectrum Configuration, the parameters and buttons are shown as below:
Start Freq: Set the start frequency of spectrum, range is 5~204 MHz.
Stop Freq: Set the stop frequency of spectrum, range is 5~204 MHz.
Center Freq and Span: Set the center frequency and span, the center frequency is shown at the center of spectrum.
Reference: Set the reference level of the spectrum based on the fact. And the spectrum peak need lower than the
reference level so that the spectrum can be fully shown in the spectrum. The range is 10-100dBuV.
Scale/Div: Range is 1-10 dB.
RBW/VBW: Auto adaptable.
Marker1/Marker2: Two Markers can be shown in the spectrum. Set the marker frequency, the level of the marker can be
shown in the spectrum.
Start: Stick start button to start capture spectrum.
Stop: Stick stop button to stop capture spectrum.
Choose Max/Min, and then stick Start button, 3 Spectrum Lines 3, including live, max hold and min hold curves will be shown
in the spectrum.
Clear Max/Min: Clear the max hold and min hold.
For Spectrum Port Enable, the parameters and buttons are shown as below:
The webpage shows all the slots and ports of the RRAS-Q-M modules.
Choose the port that you want to see the spectrum analysis, click "application", the port of spectrum analysis is enable.
Cancel the hook, click 'application', and then it will stop the port spectrum analysis.
Click the 'select all' and then click 'application', all spectrum ports are enable.
Cancel 'select all' and then click 'application', then then it will stop all the port spectrum analysis.
FBCM module Factory defaults and Reboot.
Factory default settings and Reboot can be operated from the main RRAS-Q-M page FBCM commands.
You can apply the factory default configuration and reboot the FBCM module by clicking the associated
'Apply'
button.