7.6 Hot-swap Confi guration
Click the
“Modules”
tab on the top menu bar.
Click the
“All Modules”
label on the left column of the
“Modules”
page.
For each chassis slot (1 ~ 16), you can confi gure the application module’s hot-swap mode. There are three possible settings
in the drop-down list for each slot:
Hot-swap mode
Description
Auto Download
When a new application module is inserted into a slot that previously contained the same type
of module, the last known confi guration is automatically downloaded from the ASMM module
Auto Upload
When you insert an application module into the slot, its settings are automatically uploaded to
the ASMM module
Manual
Automatic transfer of the module’s confi guration is disabled.
Note:
You can use this feature to confi gure identical application modules to automatically have the same settings.
First, automatically upload the confi guration settings you want from a pre-confi gured module. Then remove the module and change the slot’s Hot-swap
Mode from
“Auto Upload”
to
“Auto Download”
.
Now, each new module of the same type that is inserted into this slot will automatically be confi gured with the previously uploaded settings.