![technetix AIMA3000 Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/technetix/aima3000/aima3000_user-manual_1067194057.webp)
AIMA3000.RRAS/G/R Product User Manual
Technetix Group Limited
•
technetix.com
Jan/2018 - V2
57
7.10.2 Optical Input Port Signal
Check the current value of the optical input power that is displayed on the page. The acceptable range is between
-18 ~
+2 dBm
for standard RRAS models, and between
-28 ~ -12 dBm
for the RRAG.
CAUTION!
Ensure that the diff erence between the previously measured optical input power level and the displayed RRAS / RRAG
Port input level is ± 1 dBm. If not, you may need to clean the fi bre connector and optical input port.
Click on the
“Submit”
button to confi rm any changes.