AIMA3000.RRAS/G/R Product User Manual
Technetix Group Limited
•
technetix.com
Jan/2018 - V2
29
3. After the module is inserted, gently push the hinged tab until it snaps into the orange retaining clip. While
pushing down on the hinged tab, the AIMA module will mate with the power bus and will lock in into the chassis
CAUTION!
If force is required to insert a module, then it may not be correctly seated on the slide rails, or the mounting screw may
be misaligned.
4. When the module is fully seated within the chassis, on the bottom of the AIMA module, fasten the spring-loaded
mounting screw. Only use fi ngers to fasten the mounting screw. DO NOT use a screwdriver.
6.4.1 Connecting Optical Cables
Before connecting optical cables to the RRAS / RRAG / RRAR module, the input-signal level must be checked using an
optical power meter, to ensure it is within the specifi cations. All optical inputs must be checked.
6.5 Connecting the optical cables
For the convenience of the user, the AIMA3000 Chassis has a Sliding Fibre Guide to help the operator to arrange the
cables. For the specifi c steps to connect the fi bre, please refer to the instructions in section 5.4.1.
6.5 .1 Using the Sliding Fibre Guide
The sliding fi bre guide is located in the lower-left corner of the chassis if looking at the front of the chassis, and is designed
to help installation of the optical fi bre cabling. To access the sliding fi bre guide you will need to fi rst remove the rear panel
located on the back of the chassis.
1.
Unscrew the two thumbscrews on the rear panel.