22
7. VALVE SETUP AND CLEANING
7.1
Valve removal.
1.
Turn Off or disconnect the fluid pressure the syringe/fluid supply
line from the material reservoir.
2.
Switch-Off the control unit.
3.
Disconnect all valve cables.
4.
Remove the valve from the XYZ table.
5.
The valve can be now taken apart for cleaning, refer to section 7.3
for cleaning instructions.
6.
After replacing the new valve or new control unit, repeat section 4.2
for setup and section 4.3 for nozzle calibration.
7.2 Installation of new nozzle insert.
1.
Turn Off or Disconnect pressure to material syringe.
2.
Unscrew the Nut and bushing assembly from the fluid manifold using
the nozzle adjustment tool.
3.
Unscrew the nozzle bushing/insert assembly from the nozzle adjustment
nut using the nozzle installation tool.
4.
Remove the nozzle insert from the nozzle bushing.