14
Step 4:
Slowly and gently un-screw the nozzle unit (counter-clockwise), using
the nozzle adjustment tool if necessary, to move the yellow circle to the
center of the green zone.
Note: values in the yellow circle are only for
reference and it will vary from valve to valve.
Caution
: The value shown below the green zone does not make a significant
difference for the precision of the dispense process if the yellow circle is
inside the green zone.
Step 5:
If the nozzle unit is un-screwed too far out, the yellow circle will move to
the right of the green zone. Slowly screw the nozzle unit to move the
yellow circle back to the center of the green zone.
Step 6:
Once the yellow circle is at the center of the green zone, the nozzle insert is
properly calibrated. Touch the ‘Accept’ icon to save and exit
.