409-10204
Rev G
20
of 23
8. Tighten gland nut "snugly" around wire.
9. Secure cover to the electrical control box with six M4 bolts.
10. For metric air line fittings, remove Item 1. For English air line fittings, Item 1 remains.
11. If the air feed applicator requires the optional base plate clamp:
a. Install the optional base clamp (Item 11) onto the base plate.
b. Remove the back, left, base plate clamp.
12. Install the air feed applicator onto the baseplate and connect to applicable ports (see Figure 15).
13. Make sure slide valve is off (pulled away from filter).
14. Attach air supply hose to air valve assembly.
15. To turn air on, slide valve towards filter to turn air off; slide valve away from filter; make sure valve
lockout is away from slide valve.
16. To lock air in off position, turn air off and clamp lockout in location shown in Figure 15. Secure lockout
with a lock (customer supplied).
17. Reconnect power.
NOTE
The
air can be turned “off” by moving the slide valve away from the filter.
Figure 15
Double Acting Air
Cylinder Connection
Air Feed
Assembly
Spring Return Air
Cylinder Connection
Manual
Override
Auxiliary Air
Connection
Manual
Water Drain
Содержание AMP 3K/40