8.2.
Diagnostics
The control panel can be placed in a Diagnostics Mode to check operation of the machine inputs and to check
the detected AC line voltage. To place the control panel in the Diagnostics Mode.
1. Press and release Error Reset to clear any error.
2. Press and hold Error Reset for five seconds, until the control panel software version is displayed.
3. Release the Error Reset.
A screen similar to the one in Figure 18 will be presented. Each of the inputs is shown with an input identifier,
followed by an input status symbol. The input identifiers are listed in Figure 18 along with corresponding input
description. A solid dot indicates the input is “on.” A hollow dot indicates the input is “off.”
Press Error Reset to exit the diagnostic mode.
Input Identifier
Input Description
g
Guard Interlock Input
i
Insert Interlock Input
s
24V Input
t
TDC Switch Input
f
Footswitch Input
Figure 18
9.
SOTWARE VERSION IDENTIFICATION
1. Be sure the machine is turned off.
2. Turn the power to the machine on.
When the display on the control panel turns on, the control panel software version will be displayed briefly,
fol
lowed by the CPU motor controller software version. Both versions follow the format “X.XX.XX.”
10.
DISPOSAL
Contact TE for disposal.
Input Identifier
Decrease Speed
Increase Speed
Main Power Switch
Input Status
AC Line Voltage