409-10204
Rev G
3
of 23
Figure 1
1.
INTRODUCTION
This manual contains information on operation, preventive maintenance, and adjustments of the AMP 3K/40 and
AMP 5K/40 CE Terminating Machines PN 2161400-[ ] and PN 2161500-[ ] respectively. See Figure 1.
Descriptions in this manual pertain to the controls and adjustments on the AMP 3K/40 and AMP 5K/40 machines
only.
The various applicators that can be used in the machines are covered in applicator instruction sheets packaged
with each applicator. Applicator instruction sheets provide information on applicator installation, care, and
adjustment.
The specifications and requirements for the AMP 3K/40 and AMP 5K/40 CE Terminating Machines are as listed
below:
—
Deflection
: 0.13 mm [.0046 in.] Maximum per 4,448 Newtons [1,000 lb] Crimp Force
—
Noise
: Less than 82 dBa Typical at operator position with standard mechanical feed applicator
—
Weight:
77.3 Kilograms [170.4 lb]
—
Height:
585 mm [23 in.] without reel supports
—
Electrical:
100-240 Vac, 50/60 Hz, Single-Phase Current. Operating current is 3 amp.
—
Air:
620-760 kPa [90-100 psi], 2.83 liters/sec (6 scfm) When required for use with air-feed applicators
—
Physical Environment: Temperature:
4.45-40° C [40.5-104° F]
Relative Humidity:
Less than 95% (non-condensing)
Transportation and Storage:
Store in a clean, dry environment after coating
all surfaces lightly with a rust preventing oil
Содержание AMP 3K/40
Страница 7: ...409 10204 Rev G 7 of 23 Figure 5...