Insert the stripped wire into the terminal. Ensure that it is fully inserted.
Release the lever. To test to see if the connection has been made correctly, look
at the lever. If it is slightly depressed, then the connection has been made
successfully. Perform a final test by gently pulling on the wire. It should not
come out.
Fit the links according to the installation requirements
Fit the Sense
Sense
Sense
Sense link (marked JP5
JP5
JP5
JP5) if a door sense is not being used. If the door
sense is being used then leave the Sense
Sense
Sense
Sense link off.
For positive alarm action (i.e. the Alarm output is to be taken to +12 V during
an alarm condition) fit a jumper to the link marked JP2
JP2
JP2
JP2.
To change a link (JP2 shown in this example), take the jumper from ‘parked’
position on the link (it will be placed on one pin only) and place it so that it is
positioned on both of the link pins.
Figure
Figure
Figure
Figure 3
3
3
3 –––– General Wiring Arrangement for SOLO
General Wiring Arrangement for SOLO
General Wiring Arrangement for SOLO
General Wiring Arrangement for SOLOgarde
garde
garde
garde
Reader
Second Reader (Optional)
SOLOgarde
Controller
Power In
JP2
JP5