Connect all the related cable shields to the sensors, to
the feedbacks, fieldbus, references (analog and fre-
quency) and power to the bracket as shown on image
21.
6.4- CONNECTION/FIXING OF
SHIELDS ON OPDE
Moreover, it is necessary to weld the related cable
shield to the sensor to the pin “SHIELD” and to the me-
tallic cover, as shown on image 22. Connect the cable
shield of each feedback, fieldbus and references
(analog and frequency) to the related pin SHIELD as
shown on the schemes of the installation manual.
Weld the shield to the ground cable of the motor, as
shown on image 23.
Moreover, the cable shield related to the sensor, must
be connected to the pin SHIELD of its own connector.
Collegare tutti i relativi cavi schermati ai sensori, alle
retroazioni, ai bus di campo, ai riferimenti (analogici e
di frequenza) e l’alimentazione alla staffa, come mo-
strato in figura 21.
FIG. 21
FIG. 22
FIG. 23
Inoltre, è necessario saldare la schermatura del cavo
collegato al sensore al pin “SHIELD” e alla copertura
metallica, come mostrato in figura 22. Connettere il ca-
vo schermato di ogni retroazione, bus di campo e riferi-
mento (analogico e di frequenza) al relativo pin
SHIELD come mostrato sugli schemi del manuale d’in-
stallazione.
Saldare la schermatura al cavo di massa del motore,
come mostrato in figura 23.
Inoltre, la schermatura del cavo collegato al sensore,
deve essere collegato al pin SHIELD del proprio con-
nettore.
6.4-COLLEGAMENTO/FISSAGGIO
DELLE SCHERMATURE PER OPDE
Содержание OPDE
Страница 1: ...Cod MP00000B00 V_2 6 Products Tde Macno Installation OPDE...
Страница 2: ......
Страница 40: ...38 MP00000B00 V_2 6 FIG 8 Collegamenti elettrici Electrical Connections...
Страница 88: ......
Страница 89: ......