1-2
TO THE INSTALLER
Model C612
To the Installer
1
Water Connections
(Water-Cooled Machines Only)
An adequate cold water supply must be provided with a
hand shutoff valve. On the underside rear of the base
pan, two 3/8 in. IPS water connections for inlet and outlet
have been provided for easy hookup. Permanently
connect machine using 1/2 in. (12.7 mm) inside diameter
water lines. (Flexible lines are recommended, if local
codes permit.) Depending on local water conditions, it
may be advisable to install a water strainer to prevent
foreign substances from clogging the automatic water
valve. There will be only one
water-in
and one
water-out
connection.
Do not
install a hand shutoff valve on the
water-out
line! Water should always flow in this order:
first, through the automatic water valve; second, through
the condenser; and third, through the outlet fitting to an
open trap drain.
Maximum allowed water pressure of
150 psi (1,034 kPa).
IMPORTANT!
A backflow prevention device is
required on the incoming water connection side. Please
see the applicable national, state, and local codes for
determining the proper configuration. Water pressure to
the unit must not exceed 150 psi (1034 kPa).
Electrical Connections
IMPORTANT!
In the United States, this
machine is intended to be installed in accordance with
the National Electrical Code (NEC), ANSI/NFPA 701987.
The purpose of the NEC code is the practical
safeguarding of persons and property from hazards
arising from the use of electricity. This code contains
provisions considered necessary for safety.
In all other areas of the world, the machine should be
installed in accordance with the existing local codes.
Please contact your local authorities if you have any
questions.
Each machine requires one power supply for each data
label on the machine. Check the data label(s) on the
machine for branch circuit overcurrent protection or fuse,
circuit ampacity, and other electrical specifications.
See the wiring diagram provided inside the electrical box
for proper power connections.
WARNING!
This machine must be properly
grounded. Failure to do so can result in severe personal
injury from electrical shock.
WARNING!
Avoid injury.
•
DO NOT
operate the machine unless it is
properly grounded.
•
DO NOT
operate the machine with fuses larger
than specified on the machine's data label.
•
All repairs should be performed by an
authorized Taylor service technician.
•
The main power supplies to the machine must
be disconnected prior to performing installation,
repairs, or maintenance.
•
For Cord-Connected Machines:
Only Taylor
service technicians or licensed electricians may
install a plug or replacement cord on the
machine.
•
Machines that are permanently connected to
fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected
or not used for long periods, or during initial
installation, shall have protective devices to
protect against the leakage of current, such as a
GFI, installed by the authorized personnel to
local codes.
•
Stationary machines that are not equipped with
a power cord and a plug or another device to
disconnect the appliance from the power source
must have an all-pole disconnecting device with
a contact gap of at least 0.125 in. (3 mm) in the
external installation.
•
Supply cords used with this machine shall be
oil-resistant, sheathed flexible cable not lighter
than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(code designation 60245 IEC 57) installed with
the proper cord anchorage to relieve conductors
from strain, including twisting, at the terminals
and protect the insulation of the conductors from
abrasion.
!
FOLLOW YOUR LOCAL ELECTRICAL CODES.
Содержание C612
Страница 8: ...1 4 TO THE INSTALLER Model C612 To the Installer 1 Notes...
Страница 54: ...9 2 PARTS REPLACEMENT SCHEDULE Model C612 Parts Replacement Schedule 9 Notes...
Страница 58: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C612 Limited Warranty on Equipment 10 Notes...
Страница 62: ...11 4 LIMITED WARRANTY ON PARTS Model C612 Limited Warranty on Parts 11 Notes...