7-2
OPERATOR’S CHECKLIST
Model C612
Operator’s Checklist
7
Winter Storage
If the place of business is to be closed during the winter
months, it is important to protect the freezer by following
certain precautions, particularly if the building will be left
unheated and subject to freezing conditions.
Disconnect the freezer from the main power source to
prevent possible electrical damage.
On water-cooled freezers, disconnect the water supply.
Relieve pressure on the spring in the water valve. Use air
pressure on the outlet side to blow out any water
remaining in the condenser.
Important!
Failure to follow this procedure may cause
severe damage to the refrigeration system.
Your local Taylor distributor can perform this winter
storage service for you.
Wrap detachable parts of the freezer (such as the beater,
blades, driveshaft, and freezer door) and place them in a
protected dry place. Rubber trim parts and gaskets can
be protected by wrapping them with moisture-proof
paper. All parts should be thoroughly cleaned of dried mix
or lubrication accumulation, which can attract mice and
other vermin.
It is recommended that a Taylor service technician
perform winter storage draining to ensure all water has
been removed. This will guard against freezing and
rupturing of the components.
Содержание C612
Страница 8: ...1 4 TO THE INSTALLER Model C612 To the Installer 1 Notes...
Страница 54: ...9 2 PARTS REPLACEMENT SCHEDULE Model C612 Parts Replacement Schedule 9 Notes...
Страница 58: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C612 Limited Warranty on Equipment 10 Notes...
Страница 62: ...11 4 LIMITED WARRANTY ON PARTS Model C612 Limited Warranty on Parts 11 Notes...